Shallow–Deep Mixed Ground Source Heat Pump System for Sustainable Heating and Cooling: From a Small-Size Experimental Study to Evaluation of Its Interaction with the Grid

Ground source heat pump (GSHP) systems contribute to sustainable building decarbonization while confronting two intertwined challenges: long-term ground thermal imbalance in shallow borefields and the requirement for coordinated operation between thermal systems and electrical grid dynamics. Hybrid shallow–deep borefield configurations have been proposed to mitigate thermal imbalance for sustainable geothermal resource exploitation, yet their grid-interactive demand–response potential remains unexplored. Here, we develop a coupled thermal–electrical model for a shallow–deep mixed GSHP (SDBHE) system equipped with water-tank thermal storage, validated against scaled sand-tank experiments (3.5–8.3% error), and assess its year-round performance under time-of-use electricity tariffs for a 200,000 m2 residential district in cold-climate conditions. The SDBHE system reduces the required shallow borehole count by 28% and total drilling length by 22% compared with a shallow-only baseline, saving 11% on operational electricity costs over 10 years. Integrating water-tank thermal storage with a 50% load-shifting strategy yields an additional 10.9–11% cost reduction without degrading the system’s coefficient of performance. Under higher load-shifting ratios, the combined capital and operational savings reach 19–29%, with the optimal allocation assigning the incremental high-price-period load preferentially to deep boreholes (COP 6.29 versus 5.25 for shallow). These results demonstrate that integrating shallow and deep geothermal tiers with thermal storage enables both capital-efficient borefield design and economically viable demand-side grid participation. The findings are bound by the cold-climate residential context and the rule-based control scheme; field-scale validation and lifecycle cost analysis are needed to generalize the conclusions.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-08-25
DOI
https://doi.org/10.3390/su18178707
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shallow–Deep Mixed Ground Source Heat Pump System for Sustainable Heating and Cooling: From a Small-Size Experimental Study to Evaluation of Its Interaction with the Grid

Yongqiang Luo, Rujie Liu, Haoran Cheng, Chaohui Zhou
Sustainability
Geothermal Energy Systems and Applications
article

Shallow–Deep Mixed Ground Source Heat Pump System for Sustainable Heating and Cooling: From a Small-Size Experimental Study to Evaluation of Its Interaction with the Grid

Yongqiang Luo, Rujie Liu, Haoran Cheng, Chaohui Zhou
article en

Abstract

Ground source heat pump (GSHP) systems contribute to sustainable building decarbonization while confronting two intertwined challenges: long-term ground thermal imbalance in shallow borefields and the requirement for coordinated operation between thermal systems and electrical grid dynamics. Hybrid shallow–deep borefield configurations have been proposed to mitigate thermal imbalance for sustainable geothermal resource exploitation, yet their grid-interactive demand–response potential remains unexplored. Here, we develop a coupled thermal–electrical model for a shallow–deep mixed GSHP (SDBHE) system equipped with water-tank thermal storage, validated against scaled sand-tank experiments (3.5–8.3% error), and assess its year-round performance under time-of-use electricity tariffs for a 200,000 m2 residential district in cold-climate conditions. The SDBHE system reduces the required shallow borehole count by 28% and total drilling length by 22% compared with a shallow-only baseline, saving 11% on operational electricity costs over 10 years. Integrating water-tank thermal storage with a 50% load-shifting strategy yields an additional 10.9–11% cost reduction without degrading the system’s coefficient of performance. Under higher load-shifting ratios, the combined capital and operational savings reach 19–29%, with the optimal allocation assigning the incremental high-price-period load preferentially to deep boreholes (COP 6.29 versus 5.25 for shallow). These results demonstrate that integrating shallow and deep geothermal tiers with thermal storage enables both capital-efficient borefield design and economically viable demand-side grid participation. The findings are bound by the cold-climate residential context and the rule-based control scheme; field-scale validation and lifecycle cost analysis are needed to generalize the conclusions.

SustainabilityVol. 18(17)
China Three Gorges Corporation (China) (CN), Huazhong University of Science and Technology (CN)
China Yangtze Power
Decent work and economic growth
Openalex Percentile: Top 27%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.