Predicting Nitrogen Narcosis Using the Electroencephalogram (EEG) Recorded From Experienced Divers

Nitrogen narcosis causes acute cognitive impairment in divers breathing compressed air at depth, increasing injury and fatality risk. Susceptibility varies widely between individuals, making real-time cortical monitoring a potential safety tool. We recorded 32-channel electroencephalography (EEG) from 45 divers (both sexes; aged 20-55 years) at rest across four randomized crossover hyperbaric studies. We manipulated pressure (101-811 kPa) and breathing gas (air or heliox) to create two classes of recordings: narcotic (high-pressure air) or non-narcotic (low-pressure air; heliox at any pressure); our outcome was therefore gas composition, not direct cognitive impairment. We extracted 2,720 features (17 feature types × 32 channels × 5 frequency subbands) from preprocessed EEG epochs, trained six machine-learning classifiers using leave-one-participant-out cross-validation on a training set (24 participants), and evaluated the best-performing model on a test set (9 participants) and hold-out set (12 participants). Linear discriminant analysis (LDA) achieved a Matthews correlation coefficient (MCC) of 0.50 (chance ≈ 0; p = 0.001) and accuracy of 82% (baseline 76%; p = 0.001) on the test set, and MCC of 0.25 (chance ≈ 0; p = 0.001) and accuracy of 69% (baseline 69%; p = 0.77) on the hold-out set collected years later. Feature elimination retained 157 features; feature importance analysis identified zero-crossing rate, Hjorth mobility, and Katz fractal dimension at delta-band frequencies (< 4 Hz) over the anterior and posterior midline as the most important features. Easily computed EEG features with an LDA classifier can detect neurophysiological signatures of nitrogen narcosis, potentially enabling real-time passive monitoring of divers.

Authors

Institutions

Publication Details

Journal
Journal of Neurophysiology
Published
2026-08-25
DOI
https://doi.org/10.1152/jn.00167.2026
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicting Nitrogen Narcosis Using the Electroencephalogram (EEG) Recorded From Experienced Divers

Hanna van Waart, Luke E. Hallum, Lachlan D Barnes, Simon J Mitchell et al.
Journal of Neurophysiology
Cardiovascular and Diving-Related Complications
article

Predicting Nitrogen Narcosis Using the Electroencephalogram (EEG) Recorded From Experienced Divers

Hanna van Waart, Luke E. Hallum, Lachlan D Barnes, Simon J Mitchell, Jamie Sleigh, Xavier C. E. Vrijdag, Keegan W. James
article en

Abstract

Nitrogen narcosis causes acute cognitive impairment in divers breathing compressed air at depth, increasing injury and fatality risk. Susceptibility varies widely between individuals, making real-time cortical monitoring a potential safety tool. We recorded 32-channel electroencephalography (EEG) from 45 divers (both sexes; aged 20-55 years) at rest across four randomized crossover hyperbaric studies. We manipulated pressure (101-811 kPa) and breathing gas (air or heliox) to create two classes of recordings: narcotic (high-pressure air) or non-narcotic (low-pressure air; heliox at any pressure); our outcome was therefore gas composition, not direct cognitive impairment. We extracted 2,720 features (17 feature types × 32 channels × 5 frequency subbands) from preprocessed EEG epochs, trained six machine-learning classifiers using leave-one-participant-out cross-validation on a training set (24 participants), and evaluated the best-performing model on a test set (9 participants) and hold-out set (12 participants). Linear discriminant analysis (LDA) achieved a Matthews correlation coefficient (MCC) of 0.50 (chance ≈ 0; p = 0.001) and accuracy of 82% (baseline 76%; p = 0.001) on the test set, and MCC of 0.25 (chance ≈ 0; p = 0.001) and accuracy of 69% (baseline 69%; p = 0.77) on the hold-out set collected years later. Feature elimination retained 157 features; feature importance analysis identified zero-crossing rate, Hjorth mobility, and Katz fractal dimension at delta-band frequencies (< 4 Hz) over the anterior and posterior midline as the most important features. Easily computed EEG features with an LDA classifier can detect neurophysiological signatures of nitrogen narcosis, potentially enabling real-time passive monitoring of divers.

Journal of Neurophysiology
University of Auckland (NZ)
Office of Naval Research Global
Reduced inequalities
Openalex Percentile: Top 11%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.