Radiographic Projection Quality Score for the Knee (RPQS-Knee): Development and Reliability

Background/Objectives: Accurate patient positioning is essential for diagnostic quality in conventional knee radiography. Although established anatomical landmarks are routinely used to judge projection quality, assessment remains qualitative and observer-dependent. We therefore developed and validated the Radiographic Projection Quality Score for the Knee (RPQS-Knee), a standardized scoring system for objective projection quality assessment. Methods: The RPQS-Knee was derived from established radiographic positioning criteria, anatomical reference landmarks, and predefined geometrically based measurement thresholds. The final score was evaluated in 153 consecutive knee radiographic examinations, independently assessed by one radiologist and two orthopedic surgeons. Inter rater reliability was assessed using quadratically weighted Gwet’s AC2, intra rater reliability using weighted Cohen’s κ, and construct validity by correlation with separately assigned diagnostic adequacy ratings. Results: The RPQS-Knee comprises four projection-related criteria assessing fibular-head superimposition, tibial plateau alignment, and femoral-condyle congruency. Inter rater reliability was excellent for the total score (AC2 = 0.93; 95% CI, 0.92–0.95) and good to excellent for all individual items (AC2 = 0.76–0.85). Intra rater reliability ranged from κ = 0.59 to 0.81. RPQS-Knee subscores correlated strongly with diagnostic adequacy ratings (ρ = −0.69 and −0.78; both p < 0.001), providing evidence supporting construct validity. Conclusions: The RPQS-Knee translates established radiographic positioning criteria into a standardized, reproducible instrument for objective assessment of projection quality. Its excellent reliability and evidence supporting construct validity suggest that it may facilitate standardized quality assessment in clinical practice, quality assurance, and research.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-08-25
DOI
https://doi.org/10.3390/diagnostics16172703
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiographic Projection Quality Score for the Knee (RPQS-Knee): Development and Reliability

Ralf Henkelmann, Peter Melcher, Timm Denecke, Jeanette Henkelmann et al.
Diagnostics
Total Knee Arthroplasty Outcomes
article

Radiographic Projection Quality Score for the Knee (RPQS-Knee): Development and Reliability

Ralf Henkelmann, Peter Melcher, Timm Denecke, Jeanette Henkelmann, Anton Brehmer, Salim Youssef
article en

Abstract

Background/Objectives: Accurate patient positioning is essential for diagnostic quality in conventional knee radiography. Although established anatomical landmarks are routinely used to judge projection quality, assessment remains qualitative and observer-dependent. We therefore developed and validated the Radiographic Projection Quality Score for the Knee (RPQS-Knee), a standardized scoring system for objective projection quality assessment. Methods: The RPQS-Knee was derived from established radiographic positioning criteria, anatomical reference landmarks, and predefined geometrically based measurement thresholds. The final score was evaluated in 153 consecutive knee radiographic examinations, independently assessed by one radiologist and two orthopedic surgeons. Inter rater reliability was assessed using quadratically weighted Gwet’s AC2, intra rater reliability using weighted Cohen’s κ, and construct validity by correlation with separately assigned diagnostic adequacy ratings. Results: The RPQS-Knee comprises four projection-related criteria assessing fibular-head superimposition, tibial plateau alignment, and femoral-condyle congruency. Inter rater reliability was excellent for the total score (AC2 = 0.93; 95% CI, 0.92–0.95) and good to excellent for all individual items (AC2 = 0.76–0.85). Intra rater reliability ranged from κ = 0.59 to 0.81. RPQS-Knee subscores correlated strongly with diagnostic adequacy ratings (ρ = −0.69 and −0.78; both p < 0.001), providing evidence supporting construct validity. Conclusions: The RPQS-Knee translates established radiographic positioning criteria into a standardized, reproducible instrument for objective assessment of projection quality. Its excellent reliability and evidence supporting construct validity suggest that it may facilitate standardized quality assessment in clinical practice, quality assurance, and research.

DiagnosticsVol. 16(17)
University Hospital Leipzig (DE), Helios Kliniken (DE)
Partnerships for the goals
Openalex Percentile: Top 7%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines