A decoupling algorithm & its application for 3D scanning probes

The 3D scanning probe is the “eye” of precision measuring instruments, coupling errors among its axes remain an urgent problem; accurate decoupling is essential for improving probe data accuracy. This paper presents an improved algorithm that integrates Particle Swarm Optimization (PSO)、Latin Hypercube Sampling (LHS), and an Opposition-Based Learning (OBL) strategy. The inertia weight w is dynamically adjusted using a cycloidal schedule, ensuring both rapid initial convergence and refined exploration in later stages. Additionally, the cognitive and social coefficients c 1 and c 2 are linearly decreased to minimize the risk of the swarm becoming trapped in local optima. Compared with the standard PSO algorithm, the improved algorithm can obtain the global optimal solution, while the standard algorithm only achieves the local optimal solution and thus cannot be applied to probe decoupling. Compared with the LSM algorithm, the coupling matrices obtained by the two methods are basically consistent under the condition of outlier-free data. Nevertheless, when outliers exist in the dataset, the LO-PSO algorithm achieves superior robustness and decoupling accuracy relative to LSM. Tests were conducted on the original dataset, and the results show that decoupling improves the measurement accuracy of test data in the X, Y and Z directions. Compared with the pre-decoupling results, the four X-group datasets showed a maximum type-I error of 0.747%, corresponding to an average gain of 8.02%; the Y-group datasets showed a maximum type-I error of −0.956%, corresponding to an average gain of 10.82%; and the Z-group datasets showed a maximum type-I error of 1.658%, corresponding to an average gain of 8.86%. The results show that the improved algorithm significantly enhances the data accuracy of the 3D scanning probe. Under laboratory calibration test conditions, the LO-PSO algorithm achieves superior decoupling accuracy and outlier resistance robustness compared with the least squares method, and it has the engineering potential to be integrated into precision measurement software for on-site decoupling.

Authors

Institutions

Publication Details

Journal
Measurement and Control
Published
2026-08-25
DOI
https://doi.org/10.1177/00202940261479442
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A decoupling algorithm & its application for 3D scanning probes

Huixu Song, Zhaoyao Shi, Yiming Lei, Jianghao Yu
Measurement and Control
Advanced Measurement and Metrology Techniques
article

A decoupling algorithm & its application for 3D scanning probes

Huixu Song, Zhaoyao Shi, Yiming Lei, Jianghao Yu
article en

Abstract

The 3D scanning probe is the “eye” of precision measuring instruments, coupling errors among its axes remain an urgent problem; accurate decoupling is essential for improving probe data accuracy. This paper presents an improved algorithm that integrates Particle Swarm Optimization (PSO)、Latin Hypercube Sampling (LHS), and an Opposition-Based Learning (OBL) strategy. The inertia weight w is dynamically adjusted using a cycloidal schedule, ensuring both rapid initial convergence and refined exploration in later stages. Additionally, the cognitive and social coefficients c 1 and c 2 are linearly decreased to minimize the risk of the swarm becoming trapped in local optima. Compared with the standard PSO algorithm, the improved algorithm can obtain the global optimal solution, while the standard algorithm only achieves the local optimal solution and thus cannot be applied to probe decoupling. Compared with the LSM algorithm, the coupling matrices obtained by the two methods are basically consistent under the condition of outlier-free data. Nevertheless, when outliers exist in the dataset, the LO-PSO algorithm achieves superior robustness and decoupling accuracy relative to LSM. Tests were conducted on the original dataset, and the results show that decoupling improves the measurement accuracy of test data in the X, Y and Z directions. Compared with the pre-decoupling results, the four X-group datasets showed a maximum type-I error of 0.747%, corresponding to an average gain of 8.02%; the Y-group datasets showed a maximum type-I error of −0.956%, corresponding to an average gain of 10.82%; and the Z-group datasets showed a maximum type-I error of 1.658%, corresponding to an average gain of 8.86%. The results show that the improved algorithm significantly enhances the data accuracy of the 3D scanning probe. Under laboratory calibration test conditions, the LO-PSO algorithm achieves superior decoupling accuracy and outlier resistance robustness compared with the least squares method, and it has the engineering potential to be integrated into precision measurement software for on-site decoupling.

Measurement and Control
Beijing University of Technology (CN)
Openalex Percentile: Top 19%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.