Structural Stability and Modal Characteristics of Guide Vanes and Runner in a Pump-Turbine Based on Fluid–Structure Interaction

A fluid–structure interaction (FSI) model of the guide vane and runner of a pump-turbine was developed by applying unsteady hydraulic pressure loads obtained from CFD simulations to the structural surfaces. The deformation behavior, stress distribution, and modal response of the stay vane, movable guide vane, and runner were investigated under different operating conditions. The maximum deformation of the stay vane occurs at the middle section of the blade leading edge, whereas the maximum deformation of the movable guide vane is located near the trailing edge. The maximum deformation of the runner occurs at the junction between the blade leading edge and the band. Modal analysis shows that the fourth natural frequency of the movable guide vane approaches the eighth-order guide-vane passing frequency, while the sixth natural frequency of the runner approaches the fourth-order runner blade-passing frequency, suggesting a potential risk of vibration amplification.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-08-25
DOI
https://doi.org/10.3390/w18172086
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Stability and Modal Characteristics of Guide Vanes and Runner in a Pump-Turbine Based on Fluid–Structure Interaction

Jiezi Hu, Ning Ding, Yuquan Zhang, Chen Feng et al.
Water
Cavitation Phenomena in Pumps
article

Structural Stability and Modal Characteristics of Guide Vanes and Runner in a Pump-Turbine Based on Fluid–Structure Interaction

Jiezi Hu, Ning Ding, Yuquan Zhang, Chen Feng, Ancheng Wang, Wenlong Bao
article en

Abstract

A fluid–structure interaction (FSI) model of the guide vane and runner of a pump-turbine was developed by applying unsteady hydraulic pressure loads obtained from CFD simulations to the structural surfaces. The deformation behavior, stress distribution, and modal response of the stay vane, movable guide vane, and runner were investigated under different operating conditions. The maximum deformation of the stay vane occurs at the middle section of the blade leading edge, whereas the maximum deformation of the movable guide vane is located near the trailing edge. The maximum deformation of the runner occurs at the junction between the blade leading edge and the band. Modal analysis shows that the fourth natural frequency of the movable guide vane approaches the eighth-order guide-vane passing frequency, while the sixth natural frequency of the runner approaches the fourth-order runner blade-passing frequency, suggesting a potential risk of vibration amplification.

WaterVol. 18(17)
Hohai University (CN)
Affordable and clean energy
Openalex Percentile: Top 17%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Structural Stability and Modal Characteristics of Guide Vanes and Runner in a Pump-Turbine Based on Fluid–Structure Interaction — Jiezi Hu, Ning Ding, et al. · Water (2026) | TGRS Research Map | TGRS