Design and Basic Performance Evaluation of a Multi-Axis Microtome System for Precision Sectioning

Tissue sectioning is an essential preprocessing for pathological diagnosis, tissue analysis, and biomaterial evaluation, and its reliability depends on the section-thickness uniformity and repeatability. We designed and fabricated a multi-axis mechatronic microtome system to realize a target section thickness of 4-5 μm and performed sectioning experiments. The system comprises X-, Y-, and Z-axis ball screw-based linear feeding mechanisms and auxiliary posture-adjustment structures. FEM modal and static structural analyses were conducted to examine the dynamic stability and front-structure deformation. The basic driving performance was evaluated using displacement sensor-based microfeeding tests and input pulse analysis. Under a 2-pulse input, the X- and Y-axis feed displacements were 0.61301 μm and 0.59247 μm, respectively. The 3σ in-position stability values were ±0.1753 μm, ±0.1609 μm, and ±0.1528 μm for the X-, Y-, and Z-axis, respectively, confirming repeatable micro-feeding; effective strokes were approximately 100 mm for the X/Y axes and 120 mm for the Z-axis.

Authors

Publication Details

Journal
Journal of the korean society of manufacturing technology engineers
Published
2026-08-25
DOI
https://doi.org/10.7735/ksmte.2026.35.4.330
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Basic Performance Evaluation of a Multi-Axis Microtome System for Precision Sectioning

Deok‐Ho Kim, Jong-Uk An, Hak-Jun Lee, Yu-Joon Kang
Journal of the korean society of manufacturing technology engineers
Soft Robotics and Applications
article

Design and Basic Performance Evaluation of a Multi-Axis Microtome System for Precision Sectioning

Deok‐Ho Kim, Jong-Uk An, Hak-Jun Lee, Yu-Joon Kang
article en

Abstract

Tissue sectioning is an essential preprocessing for pathological diagnosis, tissue analysis, and biomaterial evaluation, and its reliability depends on the section-thickness uniformity and repeatability. We designed and fabricated a multi-axis mechatronic microtome system to realize a target section thickness of 4-5 μm and performed sectioning experiments. The system comprises X-, Y-, and Z-axis ball screw-based linear feeding mechanisms and auxiliary posture-adjustment structures. FEM modal and static structural analyses were conducted to examine the dynamic stability and front-structure deformation. The basic driving performance was evaluated using displacement sensor-based microfeeding tests and input pulse analysis. Under a 2-pulse input, the X- and Y-axis feed displacements were 0.61301 μm and 0.59247 μm, respectively. The 3σ in-position stability values were ±0.1753 μm, ±0.1609 μm, and ±0.1528 μm for the X-, Y-, and Z-axis, respectively, confirming repeatable micro-feeding; effective strokes were approximately 100 mm for the X/Y axes and 120 mm for the Z-axis.

Journal of the korean society of manufacturing technology engineersVol. 35(4)
Openalex Percentile: Top 19%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.