From Motor Efficiency to Loss Localization: A Phased, Field-Measurable Methodology for Evaluating Significant Energy Uses in Feed Mills

In the feed industry, energy efficiency is typically assessed using aggregate consumption indicators (kWh/t) or the efficiency of the electric motor in isolation, which makes it impossible to pinpoint where energy is lost along the conversion chain. This study formalizes a three-phase methodology that breaks down the useful electrical efficiency of each Significant Energy Use (SEU) into its successive stages—motor, transmission, and process—based on field-measurable variables, linking electrical conversion with the useful power model of each machine. The process efficiency of hammer mills is normalized using the Swiss Institute of Feed Technology (SFT) reference index; this constitutes a load-sensitive performance ratio, not an absolute thermodynamic efficiency. Its demonstration at the “Piensos Cienfuegos” plant (Cuba), using data from a 2015 industrial campaign, yielded overall efficiencies of 72% for the bucket elevator—conditional on the adopted nominal throughput and nameplate power factor, with a plausible range of 43–89% under coupled systematic-bias scenarios—26–28% for the hammer mills—despite motors operating at 90–92% efficiency—and 17.3% for the screw conveyor (24.7% at the processing stage). Grinding efficiency fell from 31.1% to 9.7% as the throughput of Mill III was reduced from 16 to 5 t/h, corresponding to an increase in normalized shaft-specific energy consumption from 3.50 to 11.2 kWh/t. The expanded measurement uncertainty was 11.8% (k=2), and systematic sources of uncertainty were quantified through a sensitivity analysis. The scope of this work is diagnostic: no retrofit or operational intervention was implemented at the plant, and consequently no before–after energy savings are measured or claimed. The reported efficiencies characterize the baseline condition and identify where intervention would be effective.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-08-25
DOI
https://doi.org/10.3390/eng7090430
Primary Topic
Energy Efficiency and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From Motor Efficiency to Loss Localization: A Phased, Field-Measurable Methodology for Evaluating Significant Energy Uses in Feed Mills

José Pedro Monteagudo Yanes, J.B. Robles-Ocampo, Juvenal Rodríguez‐Reséndiz, Yoisdel Castillo Álvarez et al.
Eng—Advances in Engineering
Energy Efficiency and Management
article

From Motor Efficiency to Loss Localization: A Phased, Field-Measurable Methodology for Evaluating Significant Energy Uses in Feed Mills

José Pedro Monteagudo Yanes, J.B. Robles-Ocampo, Juvenal Rodríguez‐Reséndiz, Yoisdel Castillo Álvarez, P.Y. Sevilla-Camacho, Luis Angel Iturralde Carrera, Reinier Jiménez Borges
article en

Abstract

In the feed industry, energy efficiency is typically assessed using aggregate consumption indicators (kWh/t) or the efficiency of the electric motor in isolation, which makes it impossible to pinpoint where energy is lost along the conversion chain. This study formalizes a three-phase methodology that breaks down the useful electrical efficiency of each Significant Energy Use (SEU) into its successive stages—motor, transmission, and process—based on field-measurable variables, linking electrical conversion with the useful power model of each machine. The process efficiency of hammer mills is normalized using the Swiss Institute of Feed Technology (SFT) reference index; this constitutes a load-sensitive performance ratio, not an absolute thermodynamic efficiency. Its demonstration at the “Piensos Cienfuegos” plant (Cuba), using data from a 2015 industrial campaign, yielded overall efficiencies of 72% for the bucket elevator—conditional on the adopted nominal throughput and nameplate power factor, with a plausible range of 43–89% under coupled systematic-bias scenarios—26–28% for the hammer mills—despite motors operating at 90–92% efficiency—and 17.3% for the screw conveyor (24.7% at the processing stage). Grinding efficiency fell from 31.1% to 9.7% as the throughput of Mill III was reduced from 16 to 5 t/h, corresponding to an increase in normalized shaft-specific energy consumption from 3.50 to 11.2 kWh/t. The expanded measurement uncertainty was 11.8% (k=2), and systematic sources of uncertainty were quantified through a sensitivity analysis. The scope of this work is diagnostic: no retrofit or operational intervention was implemented at the plant, and consequently no before–after energy savings are measured or claimed. The reported efficiencies characterize the baseline condition and identify where intervention would be effective.

Eng—Advances in EngineeringVol. 7(9)
Autonomous University of Queretaro (MX), University of Cienfuegos (CU), Universidad Politécnica de Chiapas (MX), Universidad Tecnológica del Perú (PE)
Affordable and clean energy
Openalex Percentile: Top 27%
Energy Efficiency and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.