Direct-on-filter Raman spectroscopy for quantifying respirable crystalline silica: Analytical challenges and practical considerations

This study evaluates the feasibility of Raman spectroscopy for quantitatively analyzing respirable crystalline silica (RCS) in coal dust samples using a direct-on-filter (DoF) approach. Key challenges include analytical sensitivity, spatial and chemical nonuniformity, fluorescence interference, and laser-induced heating effects. Although Raman spectroscopy has been proposed as a sensitive method for RCS measurement, a review of the literature shows that, when expressed as RCS mass per deposit area, the limits of quantification (LOQ) for portable Raman spectrometers (0.21–3.25 µg/mm2) are often higher than those reported for Fourier transform infrared spectroscopy (FTIR) (0.018–0.152 µg/mm2). Consequently, quantifying RCS on conventional 37 mm diameter filters is challenging due to insufficient areal loading. Concentrating samples onto a 9 mm diameter deposit area using a filter holder adapter increases Raman signal intensity by more than ten-fold, significantly enhancing sensitivity. Raman microscopes, which have small integration areas, are susceptible to deposit nonuniformity, whereas portable Raman spectrometers with larger laser beam diameters reduce this effect but remain sensitive to chemical heterogeneity. Laser-induced heating and photodegradation can remove organic compounds directly on the filter, thereby reducing both background signal and fluorescence and improving RCS measurement. These findings provide insights into the feasibility of Raman spectroscopy for RCS quantification, particularly in complex sample matrices such as coal dust.

Authors

Institutions

Publication Details

Journal
Journal of Occupational and Environmental Hygiene
Published
2026-08-25
DOI
https://doi.org/10.1080/15459624.2026.2707987
Primary Topic
Mineralogy and Gemology Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct-on-filter Raman spectroscopy for quantifying respirable crystalline silica: Analytical challenges and practical considerations

Behrooz Abbasi, Lily Raymond, John G. Watson, Mohammadreza Elahifard et al.
Journal of Occupational and Environmental Hygiene
Mineralogy and Gemology Studies
article

Direct-on-filter Raman spectroscopy for quantifying respirable crystalline silica: Analytical challenges and practical considerations

Behrooz Abbasi, Lily Raymond, John G. Watson, Mohammadreza Elahifard, Xiaoliang Wang, Bankole Osho, Y. J. Jin, Judith C. Chow
article en

Abstract

This study evaluates the feasibility of Raman spectroscopy for quantitatively analyzing respirable crystalline silica (RCS) in coal dust samples using a direct-on-filter (DoF) approach. Key challenges include analytical sensitivity, spatial and chemical nonuniformity, fluorescence interference, and laser-induced heating effects. Although Raman spectroscopy has been proposed as a sensitive method for RCS measurement, a review of the literature shows that, when expressed as RCS mass per deposit area, the limits of quantification (LOQ) for portable Raman spectrometers (0.21–3.25 µg/mm2) are often higher than those reported for Fourier transform infrared spectroscopy (FTIR) (0.018–0.152 µg/mm2). Consequently, quantifying RCS on conventional 37 mm diameter filters is challenging due to insufficient areal loading. Concentrating samples onto a 9 mm diameter deposit area using a filter holder adapter increases Raman signal intensity by more than ten-fold, significantly enhancing sensitivity. Raman microscopes, which have small integration areas, are susceptible to deposit nonuniformity, whereas portable Raman spectrometers with larger laser beam diameters reduce this effect but remain sensitive to chemical heterogeneity. Laser-induced heating and photodegradation can remove organic compounds directly on the filter, thereby reducing both background signal and fluorescence and improving RCS measurement. These findings provide insights into the feasibility of Raman spectroscopy for RCS quantification, particularly in complex sample matrices such as coal dust.

Journal of Occupational and Environmental Hygiene
University of Nevada, Reno (US), Desert Research Institute (US)
Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health
Openalex Percentile: Top 12%
Mineralogy and Gemology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.