Anchored but not safe: Rare but serious mechanical complications from peritoneal dialysis catheter suture fixation

Abstract Background Peritoneal dialysis (PD) catheter fixation techniques are frequently employed to minimize migration and optimize dialysate flow. While mechanical complications of PD catheters are well recognized, adverse events directly attributable to anchoring sutures are rarely described. We report two patients with end‐stage renal failure (ESRF) who developed clinically significant complications associated with prior catheter anchoring, illustrating both acute and chronic manifestations. Case Presentation The first case involved a 45‐year‐old female with diabetic nephropathy on PD who presented with acute abdominal pain and features of small bowel obstruction. Imaging demonstrated a transition point, and emergency laparotomy revealed internal herniation of small bowel through a loop formed by the PD catheter between an anchoring suture and its peritoneal insertion. Bowel ischemia necessitated segmental resection and primary anastomosis, followed by conversion to hemodialysis. The second case involved a 58‐year‐old male nursing‐home resident with ESRF on PD who developed recurrent catheter dysfunction. He had two prior adjustments and fixation of the current PD catheter over three years. His catheter was dysfunctional and mispositioned in the right hypochondrium on X‐ray. Laparoscopic evaluation demonstrated that the PD catheter had fractured into two. The fragments were removed, and a new catheter was inserted without suture fixation. Conclusion These cases highlight rare but clinically important complications related to fixed intra‐peritoneal points created by anchoring sutures. Such fixation may predispose to internal herniation, mechanical obstruction, or chronic catheter stress leading to spontaneous fracture. Increased awareness may inform surgical decision‐making regarding suture fixation of PD catheters.

Authors

Institutions

Publication Details

Journal
UroPrecision
Published
2026-08-25
DOI
https://doi.org/10.1002/uro2.70079
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anchored but not safe: Rare but serious mechanical complications from peritoneal dialysis catheter suture fixation

Jeffrey Leow, Candice Lee, Zhenbang Liu, Joseph Cai Sheng Wong et al.
UroPrecision
Dialysis and Renal Disease Management
article

Anchored but not safe: Rare but serious mechanical complications from peritoneal dialysis catheter suture fixation

Jeffrey Leow, Candice Lee, Zhenbang Liu, Joseph Cai Sheng Wong, Kaashi Amar Rai, Justine Zinwen Chan
article en

Abstract

Abstract Background Peritoneal dialysis (PD) catheter fixation techniques are frequently employed to minimize migration and optimize dialysate flow. While mechanical complications of PD catheters are well recognized, adverse events directly attributable to anchoring sutures are rarely described. We report two patients with end‐stage renal failure (ESRF) who developed clinically significant complications associated with prior catheter anchoring, illustrating both acute and chronic manifestations. Case Presentation The first case involved a 45‐year‐old female with diabetic nephropathy on PD who presented with acute abdominal pain and features of small bowel obstruction. Imaging demonstrated a transition point, and emergency laparotomy revealed internal herniation of small bowel through a loop formed by the PD catheter between an anchoring suture and its peritoneal insertion. Bowel ischemia necessitated segmental resection and primary anastomosis, followed by conversion to hemodialysis. The second case involved a 58‐year‐old male nursing‐home resident with ESRF on PD who developed recurrent catheter dysfunction. He had two prior adjustments and fixation of the current PD catheter over three years. His catheter was dysfunctional and mispositioned in the right hypochondrium on X‐ray. Laparoscopic evaluation demonstrated that the PD catheter had fractured into two. The fragments were removed, and a new catheter was inserted without suture fixation. Conclusion These cases highlight rare but clinically important complications related to fixed intra‐peritoneal points created by anchoring sutures. Such fixation may predispose to internal herniation, mechanical obstruction, or chronic catheter stress leading to spontaneous fracture. Increased awareness may inform surgical decision‐making regarding suture fixation of PD catheters.

UroPrecision
National University of Singapore (SG), Tan Tock Seng Hospital (SG)
Gender equality
Openalex Percentile: Top 11%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.