Improved Accuracy With a Novel Imageless Robotic-Assisted System Versus Manual Instrumentation in Unicondylar Knee Arthroplasty: A Cadaveric Study

Background Unicondylar knee arthroplasty (UKA) is a highly effective procedure for patients with end-stage single compartment osteoarthritis resulting in faster recovery and improved patient outcomes than total knee arthroplasty. However, higher revision rates remain a concern, contributing to increased utilization of robotic-assisted systems to support more accurate implant placement with the goal of reducing the most common reasons for revision. Methods This study aimed to compare the resection accuracy of a robotic-assisted unicondylar knee arthroplasty (rUKA) compared to manual instrumentation (mUKA) in a controlled cadaveric study. Six surgeons performed bilateral UKA on 40 cadaveric specimens; rUKA on 1 leg and mUKA on the other. The specimens were computed tomography scanned preprocedure and postprocedure with the achieved resection angles compared to the planned. Resection depth accuracy was assessed by measuring the resected bone (with a caliper) accounting for the saw blade thickness. Results The robotic-assisted UKA was found to have significantly greater accuracy for the angle of the resections than mUKA including tibial varus/valgus, tibial posterior slope, femoral varus/valgus, flexion/extension, and internal/external rotation. Both mUKA and rUKA procedures were found to have a high level of accuracy for the hip-knee-ankle angle and bone resection depths. rUKA had significantly fewer outliers than mUKA for the femur flexion/extension, internal/external rotation, tibial varus/valgus, and tibial flexion/extension. Conclusions The rUKA demonstrated increased accuracy of the angle of resections compared to mUKA which may support increased consistency and reproducibility of the UKA procedure.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2026-08-24
DOI
https://doi.org/10.1016/j.artd.2026.102118
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Accuracy With a Novel Imageless Robotic-Assisted System Versus Manual Instrumentation in Unicondylar Knee Arthroplasty: A Cadaveric Study

R. Patrick Courtis, Ugo Ihekweazu, David F. Dalury, Ian Leslie et al.
Arthroplasty Today
Total Knee Arthroplasty Outcomes
article

Improved Accuracy With a Novel Imageless Robotic-Assisted System Versus Manual Instrumentation in Unicondylar Knee Arthroplasty: A Cadaveric Study

R. Patrick Courtis, Ugo Ihekweazu, David F. Dalury, Ian Leslie, Gary W. Doan
article en

Abstract

Background Unicondylar knee arthroplasty (UKA) is a highly effective procedure for patients with end-stage single compartment osteoarthritis resulting in faster recovery and improved patient outcomes than total knee arthroplasty. However, higher revision rates remain a concern, contributing to increased utilization of robotic-assisted systems to support more accurate implant placement with the goal of reducing the most common reasons for revision. Methods This study aimed to compare the resection accuracy of a robotic-assisted unicondylar knee arthroplasty (rUKA) compared to manual instrumentation (mUKA) in a controlled cadaveric study. Six surgeons performed bilateral UKA on 40 cadaveric specimens; rUKA on 1 leg and mUKA on the other. The specimens were computed tomography scanned preprocedure and postprocedure with the achieved resection angles compared to the planned. Resection depth accuracy was assessed by measuring the resected bone (with a caliper) accounting for the saw blade thickness. Results The robotic-assisted UKA was found to have significantly greater accuracy for the angle of the resections than mUKA including tibial varus/valgus, tibial posterior slope, femoral varus/valgus, flexion/extension, and internal/external rotation. Both mUKA and rUKA procedures were found to have a high level of accuracy for the hip-knee-ankle angle and bone resection depths. rUKA had significantly fewer outliers than mUKA for the femur flexion/extension, internal/external rotation, tibial varus/valgus, and tibial flexion/extension. Conclusions The rUKA demonstrated increased accuracy of the angle of resections compared to mUKA which may support increased consistency and reproducibility of the UKA procedure.

Arthroplasty TodayVol. 41
St James's University Hospital (GB), Laboratoire de Synthèse Organique (FR), Texas Orthopedic Hospital (US), St. Joseph Medical Center (US)
Good health and well-being
Openalex Percentile: Top 7%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.