Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement

Objectives: To assess the clinical viability of compressed sensing magnetization, we prepared a rapid acquisition gradient echo (CS-MPRAGE) for brain volume measurement by comparing its scan time and image quality with standard MPRAGE. Methods: In this retrospective study, we analyzed a total of 40 morphologically normal MRIs from relatively young subjects (mean age 27.03 ± 5.02, range 19~40, F:M = 33:7) who underwent both CS-MPRAGE and standard MPRAGE. MRI was performed with a 3T MR scanner using a 64-channel head coil. Volumetric data analysis was conducted using commercial AI-powered quantification software. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR gray matter/white matter) were measured and compared. Qualitative analysis based on overall image quality, deep gray matter delineation, artifacts, and gray–white matter differentiation was rated on a five-point visual scoring system. Statistical analyses included paired t-tests, intraclass correlation coefficients (ICCs) and Pearson correlation. Results: CS-MPRAGE had a significantly shorter scan time than standard MPRAGE (1:46 vs. 5:20 min; p < 0.001). Whole-brain volume was similar (standard-MPRAGE, 1176.89 ± 105.36; CS-MPRAGE, 1181.14 ± 105.62 mL; r = 0.988; ICC, 0.9754–0.9931). Gray matter and regional lobe volumes were comparable, while the white matter volume was slightly larger with CS-MPRAGE. CNR of the gray–white matter was significantly higher with CS-MPRAGE (left, 30.45 ± 11.21 vs. 49.53 ± 32.71; right, 30.73 ± 11.97 vs. 46.89 ± 30.40; p = 0.0001) while SNR were similar across key brain regions. Conclusions: CS-MPRAGE provides high-quality 3D images and reliable volume data with significantly reduced acquisition time and comparable image quality.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-08-24
DOI
https://doi.org/10.3390/tomography12090121
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement

Leehi Joo, Younghee Yim, Hye Shin Ahn, Jung Bin Lee
Tomography
Advanced MRI Techniques and Applications
article

Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement

Leehi Joo, Younghee Yim, Hye Shin Ahn, Jung Bin Lee
article en

Abstract

Objectives: To assess the clinical viability of compressed sensing magnetization, we prepared a rapid acquisition gradient echo (CS-MPRAGE) for brain volume measurement by comparing its scan time and image quality with standard MPRAGE. Methods: In this retrospective study, we analyzed a total of 40 morphologically normal MRIs from relatively young subjects (mean age 27.03 ± 5.02, range 19~40, F:M = 33:7) who underwent both CS-MPRAGE and standard MPRAGE. MRI was performed with a 3T MR scanner using a 64-channel head coil. Volumetric data analysis was conducted using commercial AI-powered quantification software. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR gray matter/white matter) were measured and compared. Qualitative analysis based on overall image quality, deep gray matter delineation, artifacts, and gray–white matter differentiation was rated on a five-point visual scoring system. Statistical analyses included paired t-tests, intraclass correlation coefficients (ICCs) and Pearson correlation. Results: CS-MPRAGE had a significantly shorter scan time than standard MPRAGE (1:46 vs. 5:20 min; p < 0.001). Whole-brain volume was similar (standard-MPRAGE, 1176.89 ± 105.36; CS-MPRAGE, 1181.14 ± 105.62 mL; r = 0.988; ICC, 0.9754–0.9931). Gray matter and regional lobe volumes were comparable, while the white matter volume was slightly larger with CS-MPRAGE. CNR of the gray–white matter was significantly higher with CS-MPRAGE (left, 30.45 ± 11.21 vs. 49.53 ± 32.71; right, 30.73 ± 11.97 vs. 46.89 ± 30.40; p = 0.0001) while SNR were similar across key brain regions. Conclusions: CS-MPRAGE provides high-quality 3D images and reliable volume data with significantly reduced acquisition time and comparable image quality.

TomographyVol. 12(9)
Chung-Ang University Hospital (KR)
Openalex Percentile: Top 10%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement — Leehi Joo, Younghee Yim, et al. · Tomography (2026) | TGRS Research Map | TGRS