Study on the influence of identify orientation on acoustic-based fault diagnosis for circuit breakers in switchgear

As key equipment in the power system, the operating state of switchgear circuit breakers directly affects power grid reliability. Traditional fault diagnosis methods suffer from complex installation and high susceptibility to interference, while voiceprint diagnosis has become a research hotspot due to its non-contact, high sensitivity and easy deployment. However, the acquisition orientation (angle and distance) of sensors can significantly change voiceprint signal characteristics and reduce diagnostic accuracy. Therefore, this paper takes 10 kV switchgear circuit breakers as the research object, collects opening and closing voiceprint signals at different angles and distances through experiments, and studies the influence of sensor orientation on voiceprint characteristics. Time-frequency analysis shows that the energy of the closing signal is about twice that of the opening signal. Within the range of ±45°, the angle change has little effect on the energy (difference < 8 %), and the 0° orientation has the best signal-to-noise ratio. The angle has no significant effect on the frequency-domain characteristics, but the closing signal has richer high-frequency components. Distance experiments show that the signal energy follows the 1 / r 2 attenuation law, and the high-frequency components attenuate faster. Accordingly, this paper proposes a signal compensation method based on energy normalization, which can eliminate the spectrum distortion caused by distance and keep the signal characteristics consistent at different distances. The results provide a theoretical basis for the optimal layout of sensors in circuit breaker voiceprint diagnosis. The proposed compensation method can effectively improve the accuracy of fault diagnosis models and has important engineering application value for power equipment condition monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Measurements in Engineering
Published
2026-08-24
DOI
https://doi.org/10.21595/jme.2026.25980
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the influence of identify orientation on acoustic-based fault diagnosis for circuit breakers in switchgear

Like Zhao, Guangmin Gu, Hao Liu, Wei Zhang
Journal of Measurements in Engineering
Thermal Analysis in Power Transmission
article

Study on the influence of identify orientation on acoustic-based fault diagnosis for circuit breakers in switchgear

Like Zhao, Guangmin Gu, Hao Liu, Wei Zhang
article en

Abstract

As key equipment in the power system, the operating state of switchgear circuit breakers directly affects power grid reliability. Traditional fault diagnosis methods suffer from complex installation and high susceptibility to interference, while voiceprint diagnosis has become a research hotspot due to its non-contact, high sensitivity and easy deployment. However, the acquisition orientation (angle and distance) of sensors can significantly change voiceprint signal characteristics and reduce diagnostic accuracy. Therefore, this paper takes 10 kV switchgear circuit breakers as the research object, collects opening and closing voiceprint signals at different angles and distances through experiments, and studies the influence of sensor orientation on voiceprint characteristics. Time-frequency analysis shows that the energy of the closing signal is about twice that of the opening signal. Within the range of ±45°, the angle change has little effect on the energy (difference < 8 %), and the 0° orientation has the best signal-to-noise ratio. The angle has no significant effect on the frequency-domain characteristics, but the closing signal has richer high-frequency components. Distance experiments show that the signal energy follows the 1 / r 2 attenuation law, and the high-frequency components attenuate faster. Accordingly, this paper proposes a signal compensation method based on energy normalization, which can eliminate the spectrum distortion caused by distance and keep the signal characteristics consistent at different distances. The results provide a theoretical basis for the optimal layout of sensors in circuit breaker voiceprint diagnosis. The proposed compensation method can effectively improve the accuracy of fault diagnosis models and has important engineering application value for power equipment condition monitoring.

Journal of Measurements in Engineering
Inner Mongolia Electric Power (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 14%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on the influence of identify orientation on acoustic-based fault diagnosis for circuit breakers in switchgear — Like Zhao, Guangmin Gu, et al. · Journal of Measurements in Engineering (2026) | TGRS Research Map | TGRS