Experimental study on interface performance of UHPC panel with FRP pipe connectors partially filled with concrete

To enhance the interface performance of composite wall panels utilizing ultra-high-performance concrete (UHPC) as the outer layer, a novel connector composed of a thin-walled fiber-reinforced polymer (FRP) pipe and intersecting anchor bars was proposed. Interface shear tests were conducted to investigate the mechanical properties of the connector employed in sandwich external wall panels under four connector arrangements. The load–displacement response comprised elastic, plateau, and strengthening stages. Compared with the single-connector specimen, the multi-connector specimens increased the initial stiffness by 72–110% and the terminal displacement by 37–74%. The average ultimate load per connector ranged from 13.64 to 21.55 kN, demonstrating the beneficial spatial interaction and load-sharing effects among multiple connectors.

Authors

Institutions

Publication Details

Journal
Journal of Sustainable Cement-Based Materials
Published
2026-08-24
DOI
https://doi.org/10.1080/21650373.2026.2714903
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on interface performance of UHPC panel with FRP pipe connectors partially filled with concrete

Boyang Li, Xiangguo Wu, Yu Xing, Qinglin Zhu et al.
Journal of Sustainable Cement-Based Materials
Structural Behavior of Reinforced Concrete
article

Experimental study on interface performance of UHPC panel with FRP pipe connectors partially filled with concrete

Boyang Li, Xiangguo Wu, Yu Xing, Qinglin Zhu, Jingying Zou, Shilong Yu
article en

Abstract

To enhance the interface performance of composite wall panels utilizing ultra-high-performance concrete (UHPC) as the outer layer, a novel connector composed of a thin-walled fiber-reinforced polymer (FRP) pipe and intersecting anchor bars was proposed. Interface shear tests were conducted to investigate the mechanical properties of the connector employed in sandwich external wall panels under four connector arrangements. The load–displacement response comprised elastic, plateau, and strengthening stages. Compared with the single-connector specimen, the multi-connector specimens increased the initial stiffness by 72–110% and the terminal displacement by 37–74%. The average ultimate load per connector ranged from 13.64 to 21.55 kN, demonstrating the beneficial spatial interaction and load-sharing effects among multiple connectors.

Journal of Sustainable Cement-Based Materials
State Grid Corporation of China (China) (CN), Harbin Institute of Technology (CN), Shanghai Electric (China) (CN), Heilongjiang Electric Power Workers University (CN), Fuzhou University (CN), Ministry of Industry and Information Technology (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 13%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental study on interface performance of UHPC panel with FRP pipe connectors partially filled with concrete — Boyang Li, Xiangguo Wu, et al. · Journal of Sustainable Cement-Based Materials (2026) | TGRS Research Map | TGRS