Interference‐Resisting Mechanoluminescence Ratiometric Dosimetry

ABSTRACT Accurate and reliable radiation dosimetry is critical for applications ranging from cancer radiotherapy to nuclear safety and space exploration. While thermoluminescence and optically stimulated luminescence serve as benchmark technologies, their inherently destructive readout mechanisms preclude the straightforward, repeated verification of an absorbed dose and require complex laboratory procedures. Here, we propose a novel mechanoluminescence (ML) ratiometric dosimetry. It depends on KMgF 3 :Sm 2+,3+ that can exhibit both ML at 685 nm (Sm 2+ : 5 D 0 → 7 F 0 ) and 602 nm (Sm 3+ : 4 G 5/2 → 6 H 7/2 ) under external force stimulation. The ML intensity ratio of the 602 nm band to the 685 nm band increases linearly with increasing the radiation dosage of x‐rays. This ratiometric approach provides a robust internal self‐calibration, making the readout immune to fluctuations in stress magnitude or duration, a fatal flaw in prior ML intensity‐based methods. Therefore, we can obtain the x‐ray dose simply by pressing the KMgF 3 :Sm 2+,3+ samples. This strategy allows for multiple, nondestructive measurements, enabling on‐demand verification of radiation doses with unparalleled simplicity.

Authors

Institutions

Publication Details

Journal
Advanced Materials
Published
2026-08-24
DOI
https://doi.org/10.1002/adma.74687
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interference‐Resisting Mechanoluminescence Ratiometric Dosimetry

Leipeng Li, Feng Wang, Yanmin Yang, Tingting Deng et al.
Advanced Materials
Luminescence Properties of Advanced Materials
article

Interference‐Resisting Mechanoluminescence Ratiometric Dosimetry

Leipeng Li, Feng Wang, Yanmin Yang, Tingting Deng, Chongyang Cai, Jie Wang, Xuan Fan
article en

Abstract

ABSTRACT Accurate and reliable radiation dosimetry is critical for applications ranging from cancer radiotherapy to nuclear safety and space exploration. While thermoluminescence and optically stimulated luminescence serve as benchmark technologies, their inherently destructive readout mechanisms preclude the straightforward, repeated verification of an absorbed dose and require complex laboratory procedures. Here, we propose a novel mechanoluminescence (ML) ratiometric dosimetry. It depends on KMgF 3 :Sm 2+,3+ that can exhibit both ML at 685 nm (Sm 2+ : 5 D 0 → 7 F 0 ) and 602 nm (Sm 3+ : 4 G 5/2 → 6 H 7/2 ) under external force stimulation. The ML intensity ratio of the 602 nm band to the 685 nm band increases linearly with increasing the radiation dosage of x‐rays. This ratiometric approach provides a robust internal self‐calibration, making the readout immune to fluctuations in stress magnitude or duration, a fatal flaw in prior ML intensity‐based methods. Therefore, we can obtain the x‐ray dose simply by pressing the KMgF 3 :Sm 2+,3+ samples. This strategy allows for multiple, nondestructive measurements, enabling on‐demand verification of radiation doses with unparalleled simplicity.

Advanced Materials
Foshan University (CN), Shandong University (CN), City University of Hong Kong (HK), Hebei University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 23%
Luminescence Properties of Advanced Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.