Tumor Size Discrepancies with Different Measurement Methods in Papillary Thyroid Microcarcinoma

Abstract PurposeMeasurement of tumor size is critical for thyroid tumor management; however, optimal measurement methods and evaluation criteria remain unclear. This study aimed to quantitatively compare the papillary thyroid microcarcinoma tumor size measured by ultrasound, gross examination, and histological assessment and to determine how discrepancies between these different measurements may influence clinical decision making, such as indications for fine-needle aspiration, eligibility for active surveillance, and surgical management. Materials and methodsThis study included 412 papillary thyroid carcinoma cases with tumors of < 15 mm on preoperative ultrasound examination. ResultsThe reduction rates of gross and histological sizes compared to ultrasound sizes were 93.5% and 86.9%, respectively. Significant differences were observed between all combinations of ultrasound, gross, and histological sizes (p<0.001). Papillary thyroid microcarcinoma accounted for 42.0%, 55.6%, and 65.1% of cases, respectively. In 23 cases, the difference between the ultrasound and gross or histological sizes was >5 mm. This was because they were not cut at the maximal plane, were located in the isthmus or inferior pole, were associated with chronic thyroiditis, and were lobulated. ConclusionsWe demonstrated that the size of papillary thyroid carcinoma depends on the measurement method used. Gross and histological tumor sizes tended to be smaller than ultrasonographic sizes. Clinicians should be aware that tumors slightly exceeding 10 mm on ultrasound may ultimately be classified as papillary thyroid microcarcinoma postoperatively. Tumor location, shape, and coexisting thyroiditis can all contribute to measurement errors in ultrasound.

Authors

Institutions

Publication Details

Journal
Ultrasound International Open
Published
2026-08-24
DOI
https://doi.org/10.1055/a-2923-0168
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tumor Size Discrepancies with Different Measurement Methods in Papillary Thyroid Microcarcinoma

Akira Miyauchi, Risa Kanematsu, Miyoko Higuchi, Mitsuyoshi Hirokawa et al.
Ultrasound International Open
Thyroid Cancer Diagnosis and Treatment
article

Tumor Size Discrepancies with Different Measurement Methods in Papillary Thyroid Microcarcinoma

Akira Miyauchi, Risa Kanematsu, Miyoko Higuchi, Mitsuyoshi Hirokawa, Takashi Akamizu, Ayana Suzuki, Makoto Fujishima, M. Kawakami, Rie Goryo
article en

Abstract

Abstract PurposeMeasurement of tumor size is critical for thyroid tumor management; however, optimal measurement methods and evaluation criteria remain unclear. This study aimed to quantitatively compare the papillary thyroid microcarcinoma tumor size measured by ultrasound, gross examination, and histological assessment and to determine how discrepancies between these different measurements may influence clinical decision making, such as indications for fine-needle aspiration, eligibility for active surveillance, and surgical management. Materials and methodsThis study included 412 papillary thyroid carcinoma cases with tumors of < 15 mm on preoperative ultrasound examination. ResultsThe reduction rates of gross and histological sizes compared to ultrasound sizes were 93.5% and 86.9%, respectively. Significant differences were observed between all combinations of ultrasound, gross, and histological sizes (p<0.001). Papillary thyroid microcarcinoma accounted for 42.0%, 55.6%, and 65.1% of cases, respectively. In 23 cases, the difference between the ultrasound and gross or histological sizes was >5 mm. This was because they were not cut at the maximal plane, were located in the isthmus or inferior pole, were associated with chronic thyroiditis, and were lobulated. ConclusionsWe demonstrated that the size of papillary thyroid carcinoma depends on the measurement method used. Gross and histological tumor sizes tended to be smaller than ultrasonographic sizes. Clinicians should be aware that tumors slightly exceeding 10 mm on ultrasound may ultimately be classified as papillary thyroid microcarcinoma postoperatively. Tumor location, shape, and coexisting thyroiditis can all contribute to measurement errors in ultrasound.

Ultrasound International OpenVol. 12(CP)
Kuma Hospital (JP)
Peace, Justice and strong institutions
Openalex Percentile: Top 10%
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.