Multi‐fidelity Monte Carlo fusion for BNCT dose calculation using a dual‐branch network

BACKGROUND: Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively kills tumor cells. Its clinical implementation relies on Monte Carlo (MC)-based treatment planning systems, which are time-consuming and limit clinical workflow efficiency. PURPOSE: To address this limitation, we propose a Multi-Fidelity MC-based Dual-Branch Network (MFMC-DBN) that leverages complementary information from low- and high-fidelity MC simulations through dual-branch feature fusion, enabling accurate and efficient BNCT dose calculation. METHODS: particle histories) and patient CT information were used to predict three-dimensional dose distributions. Performance was compared with an MC denoising method and a conventional neural network (NN) approach. RESULTS: MFMC-DBN outperformed both the NN and MC denoising methods across evaluated metrics. It achieved a mean absolute percentage error (MAPE) of 1.98% in the gross tumor volume (GTV). Organ-specific MAPEs ranged from 1.1% to 3.9%, with a maximum mean absolute error (MAE) of0.28 Gy (RBE). Gamma analysis further showed high spatial agreement, with passing rates of 99.8% within the patient contour and 99.3% in the GTV under the 3%/3 mm criterion. The proposed method maintained high dosimetric accuracy while substantially accelerating BNCT dose calculation. CONCLUSIONS: MFMC-DBN effectively integrates multi-fidelity MC information through a dual-branch attention mechanism, enabling rapid and accurate 3D BNCT dose prediction. By significantly reducing computation time compared with full MC simulations while preserving dosimetric fidelity, these results support the feasibility of the proposed framework for accelerated BNCT dose calculation under a fixed beam configuration.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-08-24
DOI
https://doi.org/10.1002/mp.70646
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi‐fidelity Monte Carlo fusion for BNCT dose calculation using a dual‐branch network

Zhiqiang Wu, Xiao Yingjie, Hiroshi Watabe, Leiming Li et al.
Medical Physics
Boron Compounds in Chemistry
article

Multi‐fidelity Monte Carlo fusion for BNCT dose calculation using a dual‐branch network

Zhiqiang Wu, Xiao Yingjie, Hiroshi Watabe, Leiming Li, Xin Hong, Hiroki Tanaka, Yongquan Wang, Gan Huang
article en

Abstract

BACKGROUND: Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively kills tumor cells. Its clinical implementation relies on Monte Carlo (MC)-based treatment planning systems, which are time-consuming and limit clinical workflow efficiency. PURPOSE: To address this limitation, we propose a Multi-Fidelity MC-based Dual-Branch Network (MFMC-DBN) that leverages complementary information from low- and high-fidelity MC simulations through dual-branch feature fusion, enabling accurate and efficient BNCT dose calculation. METHODS: particle histories) and patient CT information were used to predict three-dimensional dose distributions. Performance was compared with an MC denoising method and a conventional neural network (NN) approach. RESULTS: MFMC-DBN outperformed both the NN and MC denoising methods across evaluated metrics. It achieved a mean absolute percentage error (MAPE) of 1.98% in the gross tumor volume (GTV). Organ-specific MAPEs ranged from 1.1% to 3.9%, with a maximum mean absolute error (MAE) of0.28 Gy (RBE). Gamma analysis further showed high spatial agreement, with passing rates of 99.8% within the patient contour and 99.3% in the GTV under the 3%/3 mm criterion. The proposed method maintained high dosimetric accuracy while substantially accelerating BNCT dose calculation. CONCLUSIONS: MFMC-DBN effectively integrates multi-fidelity MC information through a dual-branch attention mechanism, enabling rapid and accurate 3D BNCT dose prediction. By significantly reducing computation time compared with full MC simulations while preserving dosimetric fidelity, these results support the feasibility of the proposed framework for accelerated BNCT dose calculation under a fixed beam configuration.

Medical PhysicsVol. 53(9)
Tohoku University (JP), Lanzhou University of Technology (CN), The University of Osaka (JP)
Openalex Percentile: Top 10%
Boron Compounds in Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.