Research on Quality Inspection of PBF-LB 022Cr17Ni12Mo2 Steel Using Laser Ultrasonic Testing Technology

In this study, laser powder bed fusion (PBF-LB) 022Cr17Ni12Mo2 steel plates with dimensions of 50 mm × 50 mm × 2 mm were fabricated using a laser power of 206 W, a scanning speed of 900 mm/s, a hatch spacing of 90 μm, a layer thickness of 30 μm, and an interlayer scanning rotation of 67°. The specimens were then subjected to solution treatment at 900–1100 °C for 30 min and at 950 °C for 30–120 min. Unlike previous ultrasonic studies on additively manufactured metals, which mainly focused on defect detection, elastic-constant characterization, or residual stress evaluation, this work investigates whether solution-treatment-induced changes in grain size and dislocation density can be quantitatively reflected by laser-ultrasonic attenuation and further correlated with yield strength. Laser ultrasonic nondestructive testing using a 1064 nm pulsed laser with a pulse width of 8 ns and a pulse energy of 500 mJ was combined with metallographic observation, EBSD characterization, XRD analysis, tensile testing, and microhardness measurement. The results show that the solution-treated samples retained a single-phase γ-austenitic structure, while microstructural recovery, weakening of PBF-LB-induced cellular substructures, and partial annihilation of cell-wall dislocations led to a reduction in KAM-derived dislocation density from 2.04 × 1014 m−2 to 1.45 × 1014 m−2 and a decrease in yield strength from 466.9 MPa to 407.4 MPa. Within the present dataset, the EBSD-equivalent grain size showed an apparent positive correlation with ultrasonic attenuation, while the KAM-derived dislocation density showed an empirical negative correlation with ultrasonic attenuation. However, ultrasonic attenuation should be interpreted as a combined microstructure-sensitive response rather than as a response controlled only by EBSD-equivalent grain size or dislocation density. Based on the empirical correlations among ultrasonic attenuation, EBSD-equivalent grain size, KAM-derived dislocation density, and yield strength, a preliminary attenuation-based calibration model was established for the present solution-treated samples. The model should be regarded as an in-sample empirical calibration within the present experimental range rather than a general Hall–Petch-based predictive model. The model showed good in-sample fitting performance, with (R2) values higher than 0.85 and a maximum in-sample fitting error of 3.85%. However, because the model was established and assessed using the same eight solution-treatment conditions, it should be regarded as a preliminary calibration model within the present experimental range rather than a general predictive model. This study demonstrates the potential of laser ultrasonic attenuation for non-contact evaluation of microstructural and mechanical-property variations in solution-treated PBF-LB 022Cr17Ni12Mo2 steel.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-08-24
DOI
https://doi.org/10.3390/ma19173591
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Quality Inspection of PBF-LB 022Cr17Ni12Mo2 Steel Using Laser Ultrasonic Testing Technology

Borui Zhang, Chen Chaochao, Xianwei Yin, Qiyuan Li et al.
Materials
Additive Manufacturing Materials and Processes
article

Research on Quality Inspection of PBF-LB 022Cr17Ni12Mo2 Steel Using Laser Ultrasonic Testing Technology

Borui Zhang, Chen Chaochao, Xianwei Yin, Qiyuan Li, Anmin Yin, Wanhong Li, Chipeng Li
article en

Abstract

In this study, laser powder bed fusion (PBF-LB) 022Cr17Ni12Mo2 steel plates with dimensions of 50 mm × 50 mm × 2 mm were fabricated using a laser power of 206 W, a scanning speed of 900 mm/s, a hatch spacing of 90 μm, a layer thickness of 30 μm, and an interlayer scanning rotation of 67°. The specimens were then subjected to solution treatment at 900–1100 °C for 30 min and at 950 °C for 30–120 min. Unlike previous ultrasonic studies on additively manufactured metals, which mainly focused on defect detection, elastic-constant characterization, or residual stress evaluation, this work investigates whether solution-treatment-induced changes in grain size and dislocation density can be quantitatively reflected by laser-ultrasonic attenuation and further correlated with yield strength. Laser ultrasonic nondestructive testing using a 1064 nm pulsed laser with a pulse width of 8 ns and a pulse energy of 500 mJ was combined with metallographic observation, EBSD characterization, XRD analysis, tensile testing, and microhardness measurement. The results show that the solution-treated samples retained a single-phase γ-austenitic structure, while microstructural recovery, weakening of PBF-LB-induced cellular substructures, and partial annihilation of cell-wall dislocations led to a reduction in KAM-derived dislocation density from 2.04 × 1014 m−2 to 1.45 × 1014 m−2 and a decrease in yield strength from 466.9 MPa to 407.4 MPa. Within the present dataset, the EBSD-equivalent grain size showed an apparent positive correlation with ultrasonic attenuation, while the KAM-derived dislocation density showed an empirical negative correlation with ultrasonic attenuation. However, ultrasonic attenuation should be interpreted as a combined microstructure-sensitive response rather than as a response controlled only by EBSD-equivalent grain size or dislocation density. Based on the empirical correlations among ultrasonic attenuation, EBSD-equivalent grain size, KAM-derived dislocation density, and yield strength, a preliminary attenuation-based calibration model was established for the present solution-treated samples. The model should be regarded as an in-sample empirical calibration within the present experimental range rather than a general Hall–Petch-based predictive model. The model showed good in-sample fitting performance, with (R2) values higher than 0.85 and a maximum in-sample fitting error of 3.85%. However, because the model was established and assessed using the same eight solution-treatment conditions, it should be regarded as a preliminary calibration model within the present experimental range rather than a general predictive model. This study demonstrates the potential of laser ultrasonic attenuation for non-contact evaluation of microstructural and mechanical-property variations in solution-treated PBF-LB 022Cr17Ni12Mo2 steel.

MaterialsVol. 19(17)
Ningbo University (CN), University of Nottingham Ningbo China (CN), Ningbo University of Technology (CN), Beijing Electronic Science and Technology Institute (CN), Beijing Research Institute of Mechanical and Electrical Technology (CN), University of Science and Technology Beijing (CN)
Openalex Percentile: Top 19%
Additive Manufacturing Materials and Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.