Evaluation of Hemodynamic Data in an Ovine Model to Estimate Optimal Time for Compressor Change During Neonatal Resuscitation.

INTRODUCTION: Survival from cardiac arrest is directly and consistently linked to the quality of chest compressions (CC). Although compressor fatigue is well established, neonatal resuscitation guidelines (NRP) do not offer specific recommendations on rotation intervals beyond suggesting provider changes every 2-5 minutes. By comparison, Pediatric Advanced Life Support recommends a strict 2-minute rotation to prevent fatigue and maintain high-quality CC. METHODS: Prospective observational data from resuscitation of asphyxiated cardiac-arrested neonatal lambs to evaluate changes in chest compression rate, blood pressure, carotid blood flow with duration of CC by a single compressor. 41 near-term lambs were asphyxiated by umbilical cord occlusion until asystole resuscitated using NRP's synchronized three CC to one ventilation algorithm. RESULTS: The error rate of providing >3 or <3 CC between ventilations was <1%. CC rate and the percentage of lambs that received NRP's goal CC rate of 90/min decreased over time (p<0.005). After 91-120 seconds of chest compressions, CC rate decreased by 4% [3%,6%], carotid flow decreased by 21% [7%,35%], systolic blood pressure decreased by 3.1 [1.1,5.0] mmHg or 10% [3%,16%], and mean blood pressure decreased by 1.0 [0.3,1.7] or 7% [2%,12%] at the 95% confidence interval compared to baseline CC during the first 30 seconds (p<0.05). CONCLUSIONS: Extended duration of CC beyond 2 minutes is associated with a decrease in carotid blood flow, CC rate, systolic and mean arterial blood pressure. To maintain optimal cerebral perfusion in an ovine model of cardiac arrest, rotating compressors every two minutes may minimize fatigue-induced decrease in CC efficacy.

Authors

Publication Details

Journal
PubMed
Published
2026-08-20
DOI
https://doi.org/10.1159/neo/adsag004
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Hemodynamic Data in an Ovine Model to Estimate Optimal Time for Compressor Change During Neonatal Resuscitation.

J Li, Deepika Sankaran, Rebecca Valdez, Victoria L. Hammitt et al.
PubMed
Cardiac Arrest and Resuscitation
article

Evaluation of Hemodynamic Data in an Ovine Model to Estimate Optimal Time for Compressor Change During Neonatal Resuscitation.

J Li, Deepika Sankaran, Rebecca Valdez, Victoria L. Hammitt, Payam Vali, Evan Maher, Sylvia Bowditch, Michelle J. Lim, Morgan Hardie, Amy Lesneski, Evan Giusto, Erin Riley, Satyan Lakshminrusimha
article en

Abstract

INTRODUCTION: Survival from cardiac arrest is directly and consistently linked to the quality of chest compressions (CC). Although compressor fatigue is well established, neonatal resuscitation guidelines (NRP) do not offer specific recommendations on rotation intervals beyond suggesting provider changes every 2-5 minutes. By comparison, Pediatric Advanced Life Support recommends a strict 2-minute rotation to prevent fatigue and maintain high-quality CC. METHODS: Prospective observational data from resuscitation of asphyxiated cardiac-arrested neonatal lambs to evaluate changes in chest compression rate, blood pressure, carotid blood flow with duration of CC by a single compressor. 41 near-term lambs were asphyxiated by umbilical cord occlusion until asystole resuscitated using NRP's synchronized three CC to one ventilation algorithm. RESULTS: The error rate of providing >3 or <3 CC between ventilations was <1%. CC rate and the percentage of lambs that received NRP's goal CC rate of 90/min decreased over time (p<0.005). After 91-120 seconds of chest compressions, CC rate decreased by 4% [3%,6%], carotid flow decreased by 21% [7%,35%], systolic blood pressure decreased by 3.1 [1.1,5.0] mmHg or 10% [3%,16%], and mean blood pressure decreased by 1.0 [0.3,1.7] or 7% [2%,12%] at the 95% confidence interval compared to baseline CC during the first 30 seconds (p<0.05). CONCLUSIONS: Extended duration of CC beyond 2 minutes is associated with a decrease in carotid blood flow, CC rate, systolic and mean arterial blood pressure. To maintain optimal cerebral perfusion in an ovine model of cardiac arrest, rotating compressors every two minutes may minimize fatigue-induced decrease in CC efficacy.

PubMed
Responsible consumption and production
Openalex Percentile: Top 6%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.