Artificial Intelligence Analysis of Continuous Wave Doppler Spectra to Detect Reduced Left Ventricular Ejection Fraction

Abstract Objectives To develop an artificial intelligence (AI)-driven approach that analyzes continuous-wave (CW) Doppler spectra from the aortic valve (AV) to detect reduced (≤40%) left ventricular ejection fraction (LVEF) without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. Background Current AI solutions for LVEF assessment rely on 2D imaging and ECG signals, limiting utility when data quality is poor. Methods This retrospective study analyzed 4,231 aortic CW Doppler recordings from 3,988 examinations (3,580 patients). Preprocessing yielded 13,359 single-peak images. A CoAtNet-2 neural network was developed using patient-level training and validation cohorts and evaluated on an independent held-out test cohort. The network generated predictions for each single-peak image, and these probabilities were then averaged per examination. Maximum AV blood flow velocity and average CW Doppler pixel intensity were measured. Results LVEF ≤40% occurred in 20.8% of examinations, associating with lower maximum AV velocity and higher average pixel intensity. In the independent test cohort (782 examinations), the model achieved 85.2% accuracy, 79.0% sensitivity, 86.7% specificity, an AUC of 0.906, an NPV of 94.3%, and a PPV of 59.9%, with robust performance across subgroups. Conclusions This proof-of-concept study demonstrates the feasibility of using AI to analyze CW Doppler spectra for rapid, non-invasive identification of reduced LVEF without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. By leveraging underutilized echocardiographic Doppler data, this signal-based approach may serve as an adjunctive screening or rule-out tool, particularly when standard imaging or ECG-gated analysis is limited or delayed.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Digital Health
Published
2026-08-20
DOI
https://doi.org/10.1093/ehjdh/ztag137
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence Analysis of Continuous Wave Doppler Spectra to Detect Reduced Left Ventricular Ejection Fraction

Zofia Dzielińska, Piotr Stankiewicz, Hubert Łazarczyk, Łukasz Kalińczuk et al.
European Heart Journal - Digital Health
Cardiovascular Function and Risk Factors
article

Artificial Intelligence Analysis of Continuous Wave Doppler Spectra to Detect Reduced Left Ventricular Ejection Fraction

Zofia Dzielińska, Piotr Stankiewicz, Hubert Łazarczyk, Łukasz Kalińczuk, Michał Kania, Damian Waląg, Piotr Trochimiuk, Jacek Kwieciński, Karol Sadowski, Edyta Kaczmarska-Dyrda, Malwina Gonet, Piotr Rudzinski, Jacek Kądziela, Karolina Kryczka, Marcin Demkow, Gary S Mintz
article en

Abstract

Abstract Objectives To develop an artificial intelligence (AI)-driven approach that analyzes continuous-wave (CW) Doppler spectra from the aortic valve (AV) to detect reduced (≤40%) left ventricular ejection fraction (LVEF) without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. Background Current AI solutions for LVEF assessment rely on 2D imaging and ECG signals, limiting utility when data quality is poor. Methods This retrospective study analyzed 4,231 aortic CW Doppler recordings from 3,988 examinations (3,580 patients). Preprocessing yielded 13,359 single-peak images. A CoAtNet-2 neural network was developed using patient-level training and validation cohorts and evaluated on an independent held-out test cohort. The network generated predictions for each single-peak image, and these probabilities were then averaged per examination. Maximum AV blood flow velocity and average CW Doppler pixel intensity were measured. Results LVEF ≤40% occurred in 20.8% of examinations, associating with lower maximum AV velocity and higher average pixel intensity. In the independent test cohort (782 examinations), the model achieved 85.2% accuracy, 79.0% sensitivity, 86.7% specificity, an AUC of 0.906, an NPV of 94.3%, and a PPV of 59.9%, with robust performance across subgroups. Conclusions This proof-of-concept study demonstrates the feasibility of using AI to analyze CW Doppler spectra for rapid, non-invasive identification of reduced LVEF without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. By leveraging underutilized echocardiographic Doppler data, this signal-based approach may serve as an adjunctive screening or rule-out tool, particularly when standard imaging or ECG-gated analysis is limited or delayed.

European Heart Journal - Digital Health
Institute of Cardiology (PL), Cardiovascular Research Foundation (US)
No poverty
Openalex Percentile: Top 9%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.