Linear predictive model of viral load from air samples in simulated conditions

Airborne viruses persist and propagate in indoor settings, increasing the likelihood of outbreaks and pandemics such as the SARS-CoV-2 Pandemic. Robust air sampling methods capable of detecting, identifying, and quantifying airborne viral particles can provide critical information for mitigating these risks. However, there is still no scientific consensus on standardized protocols for recovering airborne viruses indoors. This study aimed to formulate and validate a standardized protocol for air sampling and analysis tailored to accurately detect and quantify viral aerosols in controlled indoor environments. The research utilized three concentrations of MS2 bacteriophage (1 × 106, 1 × 109, and 1 × 1012 genomic copies per liter, gc/L), a common surrogate for airborne viruses, aerosolized as particles ranging from 5 to 50 µm in an aerobiological chamber of 11,230 L. Experiments were performed under controlled conditions at 24 °C and 84% relative humidity. Air sampling employed the MD8 Airport (Sartorius) with gelatin filters, varying sampling flow rates (20, 30, and 50 L/min) and durations (5, 15, and 25 min), resulting in a recovery efficiency of 80 ± 26.5%. A linear regression model was developed to predict environmental viral particle numbers from qPCR recovery data. The results indicate that lower sampling flows (20 L/min) achieve more precise measurements for low viral concentrations, while their efficiency diminishes for extremely high concentrations over extended sampling times. The proposed methodology, combining gelatin filter samplers and qPCR, proved highly effective, detecting airborne viral loads as low as 1 × 106 gc/L during short sampling periods, providing consistent results for rapid monitoring of viral particles at low concentrations in closed environments.

Authors

Institutions

Publication Details

Journal
Journal of Occupational and Environmental Hygiene
Published
2026-08-21
DOI
https://doi.org/10.1080/15459624.2026.2709612
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linear predictive model of viral load from air samples in simulated conditions

N. Castro-del Campo, J. B. Valdez-Torres, J. D. Lira-Morales, E. C. Pérez-Zatarain et al.
Journal of Occupational and Environmental Hygiene
Infection Control and Ventilation
article

Linear predictive model of viral load from air samples in simulated conditions

N. Castro-del Campo, J. B. Valdez-Torres, J. D. Lira-Morales, E. C. Pérez-Zatarain, J. A. Medrano-Félix, J. R. Ibarra-Rodríguez, C. Chaidez-Quiroz, I. González-López, J. P. González-Gómez
article en

Abstract

Airborne viruses persist and propagate in indoor settings, increasing the likelihood of outbreaks and pandemics such as the SARS-CoV-2 Pandemic. Robust air sampling methods capable of detecting, identifying, and quantifying airborne viral particles can provide critical information for mitigating these risks. However, there is still no scientific consensus on standardized protocols for recovering airborne viruses indoors. This study aimed to formulate and validate a standardized protocol for air sampling and analysis tailored to accurately detect and quantify viral aerosols in controlled indoor environments. The research utilized three concentrations of MS2 bacteriophage (1 × 106, 1 × 109, and 1 × 1012 genomic copies per liter, gc/L), a common surrogate for airborne viruses, aerosolized as particles ranging from 5 to 50 µm in an aerobiological chamber of 11,230 L. Experiments were performed under controlled conditions at 24 °C and 84% relative humidity. Air sampling employed the MD8 Airport (Sartorius) with gelatin filters, varying sampling flow rates (20, 30, and 50 L/min) and durations (5, 15, and 25 min), resulting in a recovery efficiency of 80 ± 26.5%. A linear regression model was developed to predict environmental viral particle numbers from qPCR recovery data. The results indicate that lower sampling flows (20 L/min) achieve more precise measurements for low viral concentrations, while their efficiency diminishes for extremely high concentrations over extended sampling times. The proposed methodology, combining gelatin filter samplers and qPCR, proved highly effective, detecting airborne viral loads as low as 1 × 106 gc/L during short sampling periods, providing consistent results for rapid monitoring of viral particles at low concentrations in closed environments.

Journal of Occupational and Environmental Hygiene
Centro de Investigación en Alimentación y Desarrollo (MX), Centro de Pesquisas Oncológicas (BR)
Zero hunger
Openalex Percentile: Top 10%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.