Thermal environment characteristics of enclosed semi-translucent membrane structure industrial buildings: Effects of solar radiation and internal heat sources

Translucent membrane-enclosed industrial buildings provide an effective solution for controlling fugitive dust emissions from open-air stockpiles. However, under the combined effects of solar radiation, long-wave radiation, and convective heat transfer, the indoor thermal environment of such enclosed translucent membrane structures deteriorates significantly. In this study, an indoor ventilation airflow model was established and validated using experimental data. The indoor thermal environment of industrial membrane buildings under different ventilation conditions was investigated, by considering the coupled effects of solar radiation and heat radiation from internal heat sources. The influence of key ventilation parameters-including air inlet and outlet layout, dimensionless equivalent opening area ( A/H 2 ), and inlet height-on the internal velocity and temperature fields has been characterized. It has been shown that under a two-inlet and two-outlet configuration, the average temperature in the working zone has been measured to be 31.6 °C, the ventilation rate has reached 56.22 kg/s, and the airflow velocity above the material surface ranged from 0.4 to 0.6 m/s, indicating a limited risk of significant airflow-induced dust re-entrainment under the simulated conditions. When the dimensionless equivalent opening area ( A/H 2 ) of the inlets and outlets was varied, adjusting the dimensionless( A/H 2 )of the inlets has been found to be more effective in reducing the working zone temperature, with an optimal range of 0.34 to 0.45. The lower edge of the air inlet should not exceed 0.75 m, under which condition fresh air has been demonstrated to adequately flow through the working area, resulting in improved ventilation performance.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-08-21
DOI
https://doi.org/10.1016/j.csite.2026.108373
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal environment characteristics of enclosed semi-translucent membrane structure industrial buildings: Effects of solar radiation and internal heat sources

Pengli Yuan, Yuesheng Fan, Mengyuan Li, Linlin Li et al.
Case Studies in Thermal Engineering
Wind and Air Flow Studies
article

Thermal environment characteristics of enclosed semi-translucent membrane structure industrial buildings: Effects of solar radiation and internal heat sources

Pengli Yuan, Yuesheng Fan, Mengyuan Li, Linlin Li, Guoji Tian, Huifan Zheng
article en

Abstract

Translucent membrane-enclosed industrial buildings provide an effective solution for controlling fugitive dust emissions from open-air stockpiles. However, under the combined effects of solar radiation, long-wave radiation, and convective heat transfer, the indoor thermal environment of such enclosed translucent membrane structures deteriorates significantly. In this study, an indoor ventilation airflow model was established and validated using experimental data. The indoor thermal environment of industrial membrane buildings under different ventilation conditions was investigated, by considering the coupled effects of solar radiation and heat radiation from internal heat sources. The influence of key ventilation parameters-including air inlet and outlet layout, dimensionless equivalent opening area ( A/H 2 ), and inlet height-on the internal velocity and temperature fields has been characterized. It has been shown that under a two-inlet and two-outlet configuration, the average temperature in the working zone has been measured to be 31.6 °C, the ventilation rate has reached 56.22 kg/s, and the airflow velocity above the material surface ranged from 0.4 to 0.6 m/s, indicating a limited risk of significant airflow-induced dust re-entrainment under the simulated conditions. When the dimensionless equivalent opening area ( A/H 2 ) of the inlets and outlets was varied, adjusting the dimensionless( A/H 2 )of the inlets has been found to be more effective in reducing the working zone temperature, with an optimal range of 0.34 to 0.45. The lower edge of the air inlet should not exceed 0.75 m, under which condition fresh air has been demonstrated to adequately flow through the working area, resulting in improved ventilation performance.

Case Studies in Thermal EngineeringVol. 86
Zhongyuan University of Technology (CN), Xi'an University of Architecture and Technology (CN)
Sustainable cities and communities
Openalex Percentile: Top 16%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.