Immunohistochemistry Assay Based on Ready-To-Use Antibodies and Vendor-Recommended Protocol Settings Often Perform Suboptimally

The use of ready-to-use (RTU) antibodies in pathology laboratories has increased due to regulatory changes and the need for standardized, efficient diagnostic workflows. This study compares the performance of RTU antibodies from 2 major suppliers, Agilent (Dako Omnis platform) and Roche (BenchMark Ultra Plus system) in a Norwegian hospital setting. A total of 125 RTU antibodies were evaluated using vendor-recommended protocol settings (VRPS) and scored according to NordiQC standards. Results showed that 58 out of 62 antibodies on the Dako Omnis platform were rated as "optimal" or "good," compared with 37 out of 63 on the BenchMark Ultra Plus. Notably, 26 (41.3%) of Roche antibodies were rated "borderline" or "poor." Our study shows that several RTU antibodies perform suboptimally with VRPS. This highlights the importance of thorough validation and verification of RTU antibodies before diagnostic use. The findings underscore the need for reliable protocols from manufacturers and encourage interlaboratory collaboration to improve diagnostic consistency and quality assurance.

Authors

Institutions

Publication Details

Journal
Applied immunohistochemistry & molecular morphology
Published
2026-08-21
DOI
https://doi.org/10.1097/pai.0000000000001349
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Immunohistochemistry Assay Based on Ready-To-Use Antibodies and Vendor-Recommended Protocol Settings Often Perform Suboptimally

Dordi Lea, Ivar Skaland
Applied immunohistochemistry & molecular morphology
Clinical Laboratory Practices and Quality Control
article

Immunohistochemistry Assay Based on Ready-To-Use Antibodies and Vendor-Recommended Protocol Settings Often Perform Suboptimally

Dordi Lea, Ivar Skaland
article en

Abstract

The use of ready-to-use (RTU) antibodies in pathology laboratories has increased due to regulatory changes and the need for standardized, efficient diagnostic workflows. This study compares the performance of RTU antibodies from 2 major suppliers, Agilent (Dako Omnis platform) and Roche (BenchMark Ultra Plus system) in a Norwegian hospital setting. A total of 125 RTU antibodies were evaluated using vendor-recommended protocol settings (VRPS) and scored according to NordiQC standards. Results showed that 58 out of 62 antibodies on the Dako Omnis platform were rated as "optimal" or "good," compared with 37 out of 63 on the BenchMark Ultra Plus. Notably, 26 (41.3%) of Roche antibodies were rated "borderline" or "poor." Our study shows that several RTU antibodies perform suboptimally with VRPS. This highlights the importance of thorough validation and verification of RTU antibodies before diagnostic use. The findings underscore the need for reliable protocols from manufacturers and encourage interlaboratory collaboration to improve diagnostic consistency and quality assurance.

Applied immunohistochemistry & molecular morphology
Stavanger University Hospital (NO)
Openalex Percentile: Top 10%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Immunohistochemistry Assay Based on Ready-To-Use Antibodies and Vendor-Recommended Protocol Settings Often Perform Suboptimally — Dordi Lea, Ivar Skaland · Applied immunohistochemistry & molecular morphology (2026) | TGRS Research Map | TGRS