Flexible Non-Enzymatic Glucose Sensors via Electrospray Reduction of Copper Nanoparticles on Laser-Induced Graphene

Non-enzymatic glucose sensors have the advantages of low cost, high sensitivity, stability, and good shelf life. The porous laser-induced graphene (LIG) on flexible substrates obtained by a simple fabrication process shows good conductivity and porous morphology advantageous for sensing. Herein, flexible and non-enzymatic glucose biosensors are fabricated based on a composite of copper nanoparticles (CuNPs) anchored on LIG. The fabrication process involved a non-contact, simple, and cost-effective electrospray reduction (ESR) deposition technology, where an aqueous copper ion solution serves as the ESR precursor. The positively charged micro-scaled droplets generated by electrospray act as micro-reactors, in which the potential difference between the charged droplets and the negatively biased substrate drives the in situ reduction of Cu2+ to CuNPs. This non-contact ESR process enables the conformal deposition of CuNP catalysts on LIG, utilized here for glucose sensing. The size and distributions of the CuNPs can be tuned by the ESR parameters. The optimized sensors demonstrate excellent performance for glucose detection in KOH alkaline electrolyte, exhibiting a sensitivity of 622.9 μA·mM-1·cm-2, a limit of detection of 29.73 μM, and a wide linear range from 0.05 to 10 mM, as well as remarkable repeatability and selectivity for glucose. The ability for detection of glucose in neutral PBS buffer (pH 7.4) was also demonstrated. The ESR process provides a rapid and green fabrication of reliable non-enzymatic glucose sensors and presents a promising processing strategy for wearable and flexible health monitoring devices.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-08-21
DOI
https://doi.org/10.1021/acsami.6c12010
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Non-Enzymatic Glucose Sensors via Electrospray Reduction of Copper Nanoparticles on Laser-Induced Graphene

Congcong Zhu, Zhaoxuan Xu, Jadranka Travaš‐Sejdić, Yu Luo et al.
ACS Applied Materials & Interfaces
Electrochemical sensors and biosensors
article

Flexible Non-Enzymatic Glucose Sensors via Electrospray Reduction of Copper Nanoparticles on Laser-Induced Graphene

Congcong Zhu, Zhaoxuan Xu, Jadranka Travaš‐Sejdić, Yu Luo, Bicheng Zhu, Liangliang Zhang, Hongli Zhang, Yimeng Zhao, Penghui Lai, Z. Weng, S. Y. Jin, Linjie Du
article en

Abstract

Non-enzymatic glucose sensors have the advantages of low cost, high sensitivity, stability, and good shelf life. The porous laser-induced graphene (LIG) on flexible substrates obtained by a simple fabrication process shows good conductivity and porous morphology advantageous for sensing. Herein, flexible and non-enzymatic glucose biosensors are fabricated based on a composite of copper nanoparticles (CuNPs) anchored on LIG. The fabrication process involved a non-contact, simple, and cost-effective electrospray reduction (ESR) deposition technology, where an aqueous copper ion solution serves as the ESR precursor. The positively charged micro-scaled droplets generated by electrospray act as micro-reactors, in which the potential difference between the charged droplets and the negatively biased substrate drives the in situ reduction of Cu2+ to CuNPs. This non-contact ESR process enables the conformal deposition of CuNP catalysts on LIG, utilized here for glucose sensing. The size and distributions of the CuNPs can be tuned by the ESR parameters. The optimized sensors demonstrate excellent performance for glucose detection in KOH alkaline electrolyte, exhibiting a sensitivity of 622.9 μA·mM-1·cm-2, a limit of detection of 29.73 μM, and a wide linear range from 0.05 to 10 mM, as well as remarkable repeatability and selectivity for glucose. The ability for detection of glucose in neutral PBS buffer (pH 7.4) was also demonstrated. The ESR process provides a rapid and green fabrication of reliable non-enzymatic glucose sensors and presents a promising processing strategy for wearable and flexible health monitoring devices.

ACS Applied Materials & Interfaces
University of Auckland (NZ), Victoria University of Wellington (NZ), Victoria University (UG), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 18%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.