Achieving low intraocular pressure in normal-tension glaucoma with the Preserflo MicroShunt: comparison with primary open-angle glaucoma and the XEN-45 Gel Stent

Abstract Background Achieving low intraocular pressure (IOP) while minimizing surgical risk remains a central challenge in the management of normal-tension glaucoma (NTG). This study aimed to evaluate the efficacy and safety of the Preserflo MicroShunt (PMS) in NTG compared with primary open-angle glaucoma (POAG) and the XEN-45 Gel Stent. Methods In this retrospective dual-comparison study, the primary outcomes were 2-year complete success (≥ 30% reduction in IOP from baseline and ≤ 12 mmHg without medication) and hazard ratios (HRs) for surgical failure. Kaplan–Meier analyses and univariate Cox models were used to compare NTG PMS and POAG PMS patients (1:1 matched cohort; PMS analysis) and exploratory multivariable models for consecutive NTG PMS and NTG XEN-45 patients (NTG analysis). Secondary outcomes included bleb revision and complication rates. Results In the PMS analysis, 50 NTG patients were matched to 50 POAG patients. Two-year success rates were 69% and 45%, respectively ( p = 0.0277). NTG diagnosis was associated with a lower risk of failure (HR 0.48, 95% CI 0.24–0.96) and fewer bleb revisions. In the NTG analysis, 45 PMS patients were compared with 23 XEN-45 patients. Two-year success rates were 71% and 17%, respectively ( p < 0.0001). PMS implantation was associated with a lower risk of failure (HR 0.25, 95% CI 0.12–0.53) and fewer needling procedures. No sight-threatening complications occurred in any group. Conclusions PMS implantation enabled a high rate of sustained low IOP control, with significantly higher success rates than in matched POAG patients and NTG XEN-45 patients, while requiring fewer postoperative interventions. These findings indicate that the PMS might achieve lower IOP thresholds in NTG than previously expected requiring evaluation in larger prospective studies.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-08-21
DOI
https://doi.org/10.1186/s12886-026-05254-1
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving low intraocular pressure in normal-tension glaucoma with the Preserflo MicroShunt: comparison with primary open-angle glaucoma and the XEN-45 Gel Stent

Lasse Wolfram, Bogomil Voykov, Emil Nasyrov, Caroline J. Wenzel et al.
BMC Ophthalmology
Glaucoma and retinal disorders
article

Achieving low intraocular pressure in normal-tension glaucoma with the Preserflo MicroShunt: comparison with primary open-angle glaucoma and the XEN-45 Gel Stent

Lasse Wolfram, Bogomil Voykov, Emil Nasyrov, Caroline J. Wenzel, Felix F. Reichel
article en

Abstract

Abstract Background Achieving low intraocular pressure (IOP) while minimizing surgical risk remains a central challenge in the management of normal-tension glaucoma (NTG). This study aimed to evaluate the efficacy and safety of the Preserflo MicroShunt (PMS) in NTG compared with primary open-angle glaucoma (POAG) and the XEN-45 Gel Stent. Methods In this retrospective dual-comparison study, the primary outcomes were 2-year complete success (≥ 30% reduction in IOP from baseline and ≤ 12 mmHg without medication) and hazard ratios (HRs) for surgical failure. Kaplan–Meier analyses and univariate Cox models were used to compare NTG PMS and POAG PMS patients (1:1 matched cohort; PMS analysis) and exploratory multivariable models for consecutive NTG PMS and NTG XEN-45 patients (NTG analysis). Secondary outcomes included bleb revision and complication rates. Results In the PMS analysis, 50 NTG patients were matched to 50 POAG patients. Two-year success rates were 69% and 45%, respectively ( p = 0.0277). NTG diagnosis was associated with a lower risk of failure (HR 0.48, 95% CI 0.24–0.96) and fewer bleb revisions. In the NTG analysis, 45 PMS patients were compared with 23 XEN-45 patients. Two-year success rates were 71% and 17%, respectively ( p < 0.0001). PMS implantation was associated with a lower risk of failure (HR 0.25, 95% CI 0.12–0.53) and fewer needling procedures. No sight-threatening complications occurred in any group. Conclusions PMS implantation enabled a high rate of sustained low IOP control, with significantly higher success rates than in matched POAG patients and NTG XEN-45 patients, while requiring fewer postoperative interventions. These findings indicate that the PMS might achieve lower IOP thresholds in NTG than previously expected requiring evaluation in larger prospective studies.

BMC Ophthalmology
STZ eyetrial (DE)
Universitätsklinikum Tübingen
Good health and well-being
Openalex Percentile: Top 7%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.