Advancing process analytical technology for solution-phase reaction monitoring through data analysis and automated technologies

Process analytical technologies (PATs) provide real-time, automated measurements that enable deeper understanding of underlying chemistry, more efficient reaction conditions, and safer manufacturing processes. Recent advances in hardware and automation have allowed PATs to be integrated into increasingly complex chemical systems, while progress in computation and chemometric modelling enables researchers to extract useful chemical information from high dimensional PAT data. This thesis leverages these advances in both software and hardware to develop PAT methodologies for solution-phase reaction monitoring. First, a quantum mechanical spectral analysis (QMSA) workflow for benchtop nuclear magnetic resonance (NMR) spectroscopy is investigated. QMSA addresses the low signal dispersion commonly observed in benchtop ¹H NMR through first-principles modelling and reference data acquired on high-field NMR. Compared to the traditional indirect hard modelling approach, the proposed workflow demonstrates improved reaction monitoring performance and higher model transferability. Next, a Bayesian statistical workflow is proposed to enhance univariate calibration for infrared (IR) spectroscopy reaction monitoring. Three diagnostic probabilistic models combined with data preprocessing selection identify IR signals that improve calibration performance under non-linear conditions. Applied to a test reaction system, the workflow identified a fingerprint region signal and an unconventional preprocessing strategy that reduced prediction error by over 50% compared to conventional approaches. Finally, an online reaction monitoring platform integrating high-performance liquid chromatography (HPLC) and mass spectrometry (MS) is reported. By independently controlling dilution and solvent conditions for each detector, the system allows HPLC to monitor high-concentration species while MS captures low-level intermediates and catalyst species without chromatographic interference. Demonstrated on test reaction systems such as a Petasis multicomponent reaction and a Suzuki–Miyaura cross-coupling reaction, the platform delivers comprehensive kinetic profiles across both major and minor species in complex reaction networks.

Authors

Publication Details

Journal
Open Collections
Published
2026-08-21
DOI
https://doi.org/10.14288/1.0455281
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing process analytical technology for solution-phase reaction monitoring through data analysis and automated technologies

Jiayu Zhang
Open Collections
Innovative Microfluidic and Catalytic Techniques Innovation
article

Advancing process analytical technology for solution-phase reaction monitoring through data analysis and automated technologies

Jiayu Zhang
article en

Abstract

Process analytical technologies (PATs) provide real-time, automated measurements that enable deeper understanding of underlying chemistry, more efficient reaction conditions, and safer manufacturing processes. Recent advances in hardware and automation have allowed PATs to be integrated into increasingly complex chemical systems, while progress in computation and chemometric modelling enables researchers to extract useful chemical information from high dimensional PAT data. This thesis leverages these advances in both software and hardware to develop PAT methodologies for solution-phase reaction monitoring. First, a quantum mechanical spectral analysis (QMSA) workflow for benchtop nuclear magnetic resonance (NMR) spectroscopy is investigated. QMSA addresses the low signal dispersion commonly observed in benchtop ¹H NMR through first-principles modelling and reference data acquired on high-field NMR. Compared to the traditional indirect hard modelling approach, the proposed workflow demonstrates improved reaction monitoring performance and higher model transferability. Next, a Bayesian statistical workflow is proposed to enhance univariate calibration for infrared (IR) spectroscopy reaction monitoring. Three diagnostic probabilistic models combined with data preprocessing selection identify IR signals that improve calibration performance under non-linear conditions. Applied to a test reaction system, the workflow identified a fingerprint region signal and an unconventional preprocessing strategy that reduced prediction error by over 50% compared to conventional approaches. Finally, an online reaction monitoring platform integrating high-performance liquid chromatography (HPLC) and mass spectrometry (MS) is reported. By independently controlling dilution and solvent conditions for each detector, the system allows HPLC to monitor high-concentration species while MS captures low-level intermediates and catalyst species without chromatographic interference. Demonstrated on test reaction systems such as a Petasis multicomponent reaction and a Suzuki–Miyaura cross-coupling reaction, the platform delivers comprehensive kinetic profiles across both major and minor species in complex reaction networks.

Open Collections
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.