Fault–responsive hybrid analytical–simulation framework for electric power transmission performance monitoring

Abstract Continuous monitoring of electric power transmission systems is essential for maintaining reliable power transfer under increasingly dynamic operating conditions. Although analytical and simulation-based approaches have individually advanced transmission-system analysis, comparatively fewer studies have integrated their complementary strengths within a unified monitoring framework. This paper proposes a fault-responsive hybrid analytical–simulation framework that combines distributed-parameter transmission-line modelling based on the ABCD parameter formulation with an equivalent $$\pi $$ -model implemented in MATLAB/Simulink for continuous assessment of transmission-line performance. The framework evaluates transmission efficiency, voltage regulation, and voltage-drop index under normal and abnormal operating conditions, including voltage sag, overload, low power factor, and balanced and unbalanced faults. Validation is performed against a benchmark distributed-parameter simulation using waveform comparison together with root mean square error (RMSE) and mean absolute error (MAE). The proposed hybrid framework consistently achieved the lowest prediction errors, reducing the average transmission-efficiency MAE from approximately 0.62% for the analytical ABCD model and 0.05% for the equivalent $$\pi $$ -model to approximately 0.01%. Similarly, the average voltage-regulation MAE decreased from approximately 1.05% and 0.65% to approximately 0.07%, while accurately reproducing transmission-line behaviour during fault initiation, fault clearing, and post-fault recovery. These results demonstrate that integrating analytical modelling with dynamic simulation provides a practical, computationally efficient, and scalable framework for continuous transmission-line performance monitoring and decision support.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-08-21
DOI
https://doi.org/10.1038/s41598-026-67869-0
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault–responsive hybrid analytical–simulation framework for electric power transmission performance monitoring

Jimmy Nabende Wanzala, Johnes Obungoloch, Michael Robson Atim, Robert Mugabe
Scientific Reports
Power System Optimization and Stability
article

Fault–responsive hybrid analytical–simulation framework for electric power transmission performance monitoring

Jimmy Nabende Wanzala, Johnes Obungoloch, Michael Robson Atim, Robert Mugabe
article en

Abstract

Abstract Continuous monitoring of electric power transmission systems is essential for maintaining reliable power transfer under increasingly dynamic operating conditions. Although analytical and simulation-based approaches have individually advanced transmission-system analysis, comparatively fewer studies have integrated their complementary strengths within a unified monitoring framework. This paper proposes a fault-responsive hybrid analytical–simulation framework that combines distributed-parameter transmission-line modelling based on the ABCD parameter formulation with an equivalent $$\pi $$ -model implemented in MATLAB/Simulink for continuous assessment of transmission-line performance. The framework evaluates transmission efficiency, voltage regulation, and voltage-drop index under normal and abnormal operating conditions, including voltage sag, overload, low power factor, and balanced and unbalanced faults. Validation is performed against a benchmark distributed-parameter simulation using waveform comparison together with root mean square error (RMSE) and mean absolute error (MAE). The proposed hybrid framework consistently achieved the lowest prediction errors, reducing the average transmission-efficiency MAE from approximately 0.62% for the analytical ABCD model and 0.05% for the equivalent $$\pi $$ -model to approximately 0.01%. Similarly, the average voltage-regulation MAE decreased from approximately 1.05% and 0.65% to approximately 0.07%, while accurately reproducing transmission-line behaviour during fault initiation, fault clearing, and post-fault recovery. These results demonstrate that integrating analytical modelling with dynamic simulation provides a practical, computationally efficient, and scalable framework for continuous transmission-line performance monitoring and decision support.

Scientific Reports
Mbarara University of Science and Technology (UG), Busitema University (UG), Kabale University (UG)
Affordable and clean energy
Openalex Percentile: Top 19%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.