Pulseometry: A differential readout to compensate signal drift of potentiometric probes

Ion selective electrodes are widely used sensors in point-of-care testing devices to assay electrolytes in whole blood samples. With single-use system, the first solution contact normally results in an important signal drift that negatively affects measurement accuracy. In this work, we propose an approach coined pulseometry to compensate for signal drift. The potentiometric signal is processed through a differential circuit incorporating RC components of different time constants. The differential potential will remain constant for a slowly drifting baseline, while a rapid potential change will result in a peak-shaped difference signal that may be baseline subtracted and integrated to extract the components information. The method was successfully integrated into mass fabricated, microfluidic test cards used in commercial blood gas electrolyte analyzers. Blood calcium levels from three individuals were measured, giving SDs of 0.008 to 0.024 mM, improving precision by 36 to 67% compared to potentiometry. These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.

Authors

Institutions

Publication Details

Journal
Science Advances
Published
2026-08-21
DOI
https://doi.org/10.1126/sciadv.aef5993
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulseometry: A differential readout to compensate signal drift of potentiometric probes

Eric Bakker, Yaotian Wu, Yu Qin, Junyu Zhou
Science Advances
Analytical Chemistry and Sensors
article

Pulseometry: A differential readout to compensate signal drift of potentiometric probes

Eric Bakker, Yaotian Wu, Yu Qin, Junyu Zhou
article en

Abstract

Ion selective electrodes are widely used sensors in point-of-care testing devices to assay electrolytes in whole blood samples. With single-use system, the first solution contact normally results in an important signal drift that negatively affects measurement accuracy. In this work, we propose an approach coined pulseometry to compensate for signal drift. The potentiometric signal is processed through a differential circuit incorporating RC components of different time constants. The differential potential will remain constant for a slowly drifting baseline, while a rapid potential change will result in a peak-shaped difference signal that may be baseline subtracted and integrated to extract the components information. The method was successfully integrated into mass fabricated, microfluidic test cards used in commercial blood gas electrolyte analyzers. Blood calcium levels from three individuals were measured, giving SDs of 0.008 to 0.024 mM, improving precision by 36 to 67% compared to potentiometry. These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.

Science AdvancesVol. 12(34)
University of Geneva (CH), Easterseals (US)
Openalex Percentile: Top 19%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulseometry: A differential readout to compensate signal drift of potentiometric probes — Eric Bakker, Yaotian Wu, et al. · Science Advances (2026) | TGRS Research Map | TGRS