Right Atrial Strain as a Predictor of Atrial High-Rate Episodes in Pacemaker Patients: A Case-Control Pilot Study.

BACKGROUND: Atrial high-rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) represent subclinical atrial tachyarrhythmias that are strongly associated with an increased risk of progression to clinical atrial fibrillation (AF) and thromboembolic events. The underlying bi-atrial electrical and mechanical remodeling that precedes AHRE remains incompletely understood, particularly the role of right atrial (RA) function. OBJECTIVES: This study aimed to identify combined electrocardiographic (ECG) and echocardiographic predictors of device-detected AHRE in patients with dual-chamber pacemakers, with a specific focus on the incremental predictive value of RA strain assessed by two-dimensional speckle-tracking echocardiography (2D-STE). METHODS: A single-center, case-control study was conducted on a cohort of prospectively followed patients involving 60 adult patients with dual-chamber (DDD) pacemakers, divided into two groups: 30 patients with device-detected AHRE (AHRE⁺) and 30 age- and sex-matched controls without AHRE (AHRE⁻). All participants underwent detailed clinical evaluation, 12-lead ECG analysis (including P-wave duration and dispersion), and comprehensive transthoracic echocardiography, including 2D-STE for assessment of RA reservoir strain (RASr) and contractile strain (RASct). AHRE was defined as an atrial tachyarrhythmia ≥180 bpm lasting ≥6 min, verified by intracardiac electrograms. RESULTS: AHRE⁺ patients exhibited significantly prolonged P-wave duration (118 ± 14 ms vs 108 ± 12 ms; p = 0.04) and greater P-wave dispersion (42 ± 8 ms vs 36 ± 7 ms; p = 0.03). They also Echocardiographically, they demonstrated significantly higher left atrial volume index (LAVI) (34.2 ± 6.8 vs 28.5 ± 5.2 mL/m²; p = 0.012) and right atrial volume index (RAVI) (26.4 ± 5.1 vs 22.7 ± 4.3 mL/m²; p = 0.028), RA function was markedly impaired in the AHRE⁺ group, with reduced right atrial reservoir and contractile strain (RASr 15.8 % vs 25.9 %, p = 0.041; RASct -2.0 % vs -11.6 %, p = 0.012). Multivariate analysis identified four independent predictors of AHRE: RASr < 20 % (OR 3.8; 95 % CI 1.7-8.4; p < 0.001), LAVI ≥ 34 mL/m² (OR 3.1; 95 % CI 1.5-6.2; p = 0.003), P-wave dispersion ≥ 40 ms (OR 2.6; 95 % CI 1.2-5.8; p = 0.008), Ventricular pacing > 90 % (OR 2.1; 95 % CI 1.0-4.4; p = 0.032). The model achieved strong discrimination (AUC = 0.84; 95 % CI 0.76-0.92) and good calibration (Hosmer-Lemeshow p = 0.47). CONCLUSIONS: The occurrence of AHRE in DDD pacemaker patients is independently associated with a combination of electrical and mechanical bi-atrial remodeling. Impaired right atrial strain (RASr < 20%) provides significant incremental predictive value beyond conventional metrics like P-wave dispersion and left atrial enlargement. Integrating RA strain into routine echocardiographic assessment may serve as a powerful, early marker for risk stratification of atrial arrhythmogenic remodeling in this high-risk population.

Authors

Publication Details

Journal
PubMed
Published
2026-08-20
DOI
https://doi.org/10.1159/crd/absag006
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Right Atrial Strain as a Predictor of Atrial High-Rate Episodes in Pacemaker Patients: A Case-Control Pilot Study.

Khaled Abouelmagd, Ayman Ahmed Gad, Waseem Omar Ahmed, Ahmed Ali Fahmy Mostafa et al.
PubMed
Atrial Fibrillation Management and Outcomes
article

Right Atrial Strain as a Predictor of Atrial High-Rate Episodes in Pacemaker Patients: A Case-Control Pilot Study.

Khaled Abouelmagd, Ayman Ahmed Gad, Waseem Omar Ahmed, Ahmed Ali Fahmy Mostafa, Hosam El Din Hosni Helal, Mohamed Adel Attia
article en

Abstract

BACKGROUND: Atrial high-rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) represent subclinical atrial tachyarrhythmias that are strongly associated with an increased risk of progression to clinical atrial fibrillation (AF) and thromboembolic events. The underlying bi-atrial electrical and mechanical remodeling that precedes AHRE remains incompletely understood, particularly the role of right atrial (RA) function. OBJECTIVES: This study aimed to identify combined electrocardiographic (ECG) and echocardiographic predictors of device-detected AHRE in patients with dual-chamber pacemakers, with a specific focus on the incremental predictive value of RA strain assessed by two-dimensional speckle-tracking echocardiography (2D-STE). METHODS: A single-center, case-control study was conducted on a cohort of prospectively followed patients involving 60 adult patients with dual-chamber (DDD) pacemakers, divided into two groups: 30 patients with device-detected AHRE (AHRE⁺) and 30 age- and sex-matched controls without AHRE (AHRE⁻). All participants underwent detailed clinical evaluation, 12-lead ECG analysis (including P-wave duration and dispersion), and comprehensive transthoracic echocardiography, including 2D-STE for assessment of RA reservoir strain (RASr) and contractile strain (RASct). AHRE was defined as an atrial tachyarrhythmia ≥180 bpm lasting ≥6 min, verified by intracardiac electrograms. RESULTS: AHRE⁺ patients exhibited significantly prolonged P-wave duration (118 ± 14 ms vs 108 ± 12 ms; p = 0.04) and greater P-wave dispersion (42 ± 8 ms vs 36 ± 7 ms; p = 0.03). They also Echocardiographically, they demonstrated significantly higher left atrial volume index (LAVI) (34.2 ± 6.8 vs 28.5 ± 5.2 mL/m²; p = 0.012) and right atrial volume index (RAVI) (26.4 ± 5.1 vs 22.7 ± 4.3 mL/m²; p = 0.028), RA function was markedly impaired in the AHRE⁺ group, with reduced right atrial reservoir and contractile strain (RASr 15.8 % vs 25.9 %, p = 0.041; RASct -2.0 % vs -11.6 %, p = 0.012). Multivariate analysis identified four independent predictors of AHRE: RASr < 20 % (OR 3.8; 95 % CI 1.7-8.4; p < 0.001), LAVI ≥ 34 mL/m² (OR 3.1; 95 % CI 1.5-6.2; p = 0.003), P-wave dispersion ≥ 40 ms (OR 2.6; 95 % CI 1.2-5.8; p = 0.008), Ventricular pacing > 90 % (OR 2.1; 95 % CI 1.0-4.4; p = 0.032). The model achieved strong discrimination (AUC = 0.84; 95 % CI 0.76-0.92) and good calibration (Hosmer-Lemeshow p = 0.47). CONCLUSIONS: The occurrence of AHRE in DDD pacemaker patients is independently associated with a combination of electrical and mechanical bi-atrial remodeling. Impaired right atrial strain (RASr < 20%) provides significant incremental predictive value beyond conventional metrics like P-wave dispersion and left atrial enlargement. Integrating RA strain into routine echocardiographic assessment may serve as a powerful, early marker for risk stratification of atrial arrhythmogenic remodeling in this high-risk population.

PubMed
Good health and well-being
Openalex Percentile: Top 10%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.