Fully automated analysis of cardiotoxicity surveillance echocardiograms: A direct test-retest precision comparison with experts

Abstract Aims Serial imaging demands measurement precision – particularly for cardiotoxicity screening where small changes gatekeeper major management decisions. Automated measurement using artificial intelligence (AI)-based techniques should reduce variability and increase confidence for detection of true interval change. We directly compared the precision of fully-automated AI versus expert manual analysis of left ventricular function by echocardiography. Methods and Results Consecutive cancer patients referred for cardiotoxicity monitoring underwent same day repeat 2D echocardiography (n=60, 83% female, mean age 52±12years, mean LVEF 57±7%), with 3D acquisition where feasible (n=45). All 2D images underwent blinded manual analysis by fully automated analysis software and four individual experts. Quantitative 2D LVEF measurement was feasible in 97% scans by both methods. Mean absolute difference (MAD) between repeat scans was significantly lower for AI than experts for both 2D LVEF (3.6% [CI 2.8–4.4] vs 6.6% [CI 5.3–7.9], p=0.011) and global longitudinal strain (1.5% [CI 1.1–1.9] vs 2.5% [CI 2.0–3.0], p=0.006). In participants with 3DE datasets, 3D LVEF MAD was lower than manual 2D LVEF (3.6% [CI 2.8-4.6] vs 6.4% [CI 5.0-8.0], p=0.006) but comparable to AI-derived 2D LVEF (3.5% [CI 2.9-4.2], p=0.4). In a subset (n=48) also with same day cardiovascular magnetic resonance studies (CMR), AI 2DE analysis demonstrated stronger agreement with CMR than expert 2DE analysis (LVEF MAD 5.0% [CI 4.1-5.9] vs 7.8% ([CI 6.6-9.0] p=0.006). Conclusions In cancer patients at risk of cardiotoxicity, the precision of 2D echocardiographic AI analysis exceeds that of experts, matching that of 3D LVEF assessment.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Imaging Methods and Practice
Published
2026-08-20
DOI
https://doi.org/10.1093/ehjimp/qyag142
Primary Topic
Chemotherapy-induced cardiotoxicity and mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fully automated analysis of cardiotoxicity surveillance echocardiograms: A direct test-retest precision comparison with experts

Adam Ioannou, Verónica Culotta, Anish Bhuva, Benjamin Dowsing et al.
European Heart Journal - Imaging Methods and Practice
Chemotherapy-induced cardiotoxicity and mitigation
article

Fully automated analysis of cardiotoxicity surveillance echocardiograms: A direct test-retest precision comparison with experts

Adam Ioannou, Verónica Culotta, Anish Bhuva, Benjamin Dowsing, Beth Unsworth, Marianna Fontana, Rhodri Davies, Katia Menacho, Ana Ferreira, Benjamin Meredith, Mark Westwood, Charlotte Manisty, Guy Lloyd, Arjun Ghosh, Matthew Shun-Shin, Leon Menezes, James C Moon
article en

Abstract

Abstract Aims Serial imaging demands measurement precision – particularly for cardiotoxicity screening where small changes gatekeeper major management decisions. Automated measurement using artificial intelligence (AI)-based techniques should reduce variability and increase confidence for detection of true interval change. We directly compared the precision of fully-automated AI versus expert manual analysis of left ventricular function by echocardiography. Methods and Results Consecutive cancer patients referred for cardiotoxicity monitoring underwent same day repeat 2D echocardiography (n=60, 83% female, mean age 52±12years, mean LVEF 57±7%), with 3D acquisition where feasible (n=45). All 2D images underwent blinded manual analysis by fully automated analysis software and four individual experts. Quantitative 2D LVEF measurement was feasible in 97% scans by both methods. Mean absolute difference (MAD) between repeat scans was significantly lower for AI than experts for both 2D LVEF (3.6% [CI 2.8–4.4] vs 6.6% [CI 5.3–7.9], p=0.011) and global longitudinal strain (1.5% [CI 1.1–1.9] vs 2.5% [CI 2.0–3.0], p=0.006). In participants with 3DE datasets, 3D LVEF MAD was lower than manual 2D LVEF (3.6% [CI 2.8-4.6] vs 6.4% [CI 5.0-8.0], p=0.006) but comparable to AI-derived 2D LVEF (3.5% [CI 2.9-4.2], p=0.4). In a subset (n=48) also with same day cardiovascular magnetic resonance studies (CMR), AI 2DE analysis demonstrated stronger agreement with CMR than expert 2DE analysis (LVEF MAD 5.0% [CI 4.1-5.9] vs 7.8% ([CI 6.6-9.0] p=0.006). Conclusions In cancer patients at risk of cardiotoxicity, the precision of 2D echocardiographic AI analysis exceeds that of experts, matching that of 3D LVEF assessment.

European Heart Journal - Imaging Methods and Practice
St Bartholomew's Hospital (GB), Imperial College Healthcare NHS Trust (GB), Lung Institute (US), Amyloidosis Foundation (US), University College London (GB), Imperial College London (GB)
Openalex Percentile: Top 10%
Chemotherapy-induced cardiotoxicity and mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.