Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: A phantom study

This study was designed to assess the feasibility of dual-energy cone-beam CT (DE-CBCT) and the associated image processing algorithms to improve delayed phase iodine enhancement. An anthropomorphic adult head phantom with iodine inserts in maxillofacial regions was imaged using a clinical CBCT and a helical CT scanner. DE-CBCT was acquired sequentially at 80 and 120 kV, and helical CT at 100 kV (routine clinical protocol), with radiation doses matched within 5%. Virtual monochromatic images (VMIs) at 50 and 200 keV were generated with (VMI+) and without (VMI) noise-optimized frequency splitting algorithm. Evaluation included Hounsfield Unit (HU) agreement with helical CT, iodine contrast, contrast-to-noise ratio (CNR), artifact reduction, and subjective radiologist assessment of target visibility. VMI50 and VMI50+ demonstrated the strongest HU agreement with CT. VMI50+ produced significantly better contrast than CBCT in the maxillary sinus region (mean percentage change 40.7% (15.3-66.1%); p < 0.05), while improvements were minor in the mandibular region (9.7% (3.0-16.5%); p < 0.05). VMI50+ significantly increased CNR in the maxillary sinus compared with CBCT (3.3 vs. 2.8; p < 0.05), with no significant difference in the mandibular region. Although DE-CBCT increased contrast and reduced artefacts, it did not reveal any additional targets compared with routine CBCT. DE-CBCT with VMI and frequency splitting improves HU agreement with CT, slightly improves soft tissue visualization, and reduces artifacts in head and neck phantom imaging.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-08-21
DOI
https://doi.org/10.1088/2057-1976/ae9cc2
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: A phantom study

Michaela K. Bode, Mikael Brix, Veli-Pekka Riekki, Dinidu Jayakody
Biomedical Physics & Engineering Express
Advanced X-ray and CT Imaging
article

Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: A phantom study

Michaela K. Bode, Mikael Brix, Veli-Pekka Riekki, Dinidu Jayakody
article en

Abstract

This study was designed to assess the feasibility of dual-energy cone-beam CT (DE-CBCT) and the associated image processing algorithms to improve delayed phase iodine enhancement. An anthropomorphic adult head phantom with iodine inserts in maxillofacial regions was imaged using a clinical CBCT and a helical CT scanner. DE-CBCT was acquired sequentially at 80 and 120 kV, and helical CT at 100 kV (routine clinical protocol), with radiation doses matched within 5%. Virtual monochromatic images (VMIs) at 50 and 200 keV were generated with (VMI+) and without (VMI) noise-optimized frequency splitting algorithm. Evaluation included Hounsfield Unit (HU) agreement with helical CT, iodine contrast, contrast-to-noise ratio (CNR), artifact reduction, and subjective radiologist assessment of target visibility. VMI50 and VMI50+ demonstrated the strongest HU agreement with CT. VMI50+ produced significantly better contrast than CBCT in the maxillary sinus region (mean percentage change 40.7% (15.3-66.1%); p < 0.05), while improvements were minor in the mandibular region (9.7% (3.0-16.5%); p < 0.05). VMI50+ significantly increased CNR in the maxillary sinus compared with CBCT (3.3 vs. 2.8; p < 0.05), with no significant difference in the mandibular region. Although DE-CBCT increased contrast and reduced artefacts, it did not reveal any additional targets compared with routine CBCT. DE-CBCT with VMI and frequency splitting improves HU agreement with CT, slightly improves soft tissue visualization, and reduces artifacts in head and neck phantom imaging.

Biomedical Physics & Engineering Express
Oulu University Hospital (FI), University of Oulu (FI)
Oulun Yliopisto, Business Finland
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: A phantom study — Michaela K. Bode, Mikael Brix, et al. · Biomedical Physics & Engineering Express (2026) | TGRS Research Map | TGRS