Power and Fatigue–Load Assessment of Static Wake Steering in a Floating Wind Farm with 15 MW Turbines

Static wake steering can increase wind-farm power production, but its application to floating offshore wind farms requires assessment of the coupled wake, platform, structural, and station-keeping response. This study evaluates whether power-maximizing static yaw setpoints identified using the steady, control-oriented FLORIS model retain their benefit when transferred without re-optimization to a coupled FAST.Farm floating wind-farm model. The reference farm comprises four IEA Wind 15 MW turbines mounted on VolturnUS-S semi-submersible platforms. Greedy and static wake-steering operations are compared at three below-rated wind speeds, three sea states, and five matched turbulent-inflow realizations, resulting in 90 farm-level FAST.Farm simulations. Wake behavior is characterized through wake-center deflection, meandering, and velocity-deficit profiles, while turbine and mooring fatigue responses are evaluated using paired damage-equivalent-load statistics. Static wake steering increases mean farm power under all nine investigated wind–wave conditions. The gains are approximately 5.1–5.2% at 7ms−1, 5.0–5.1% at 8ms−1, and 4.0–4.2% at 9ms−1, with all paired 95% confidence intervals remaining above zero. The gain results from a power redistribution in which the intentionally yawed upstream turbine incurs a local loss that is exceeded by the combined recovery of the downstream turbines. The fatigue response is strongly component- and turbine-dependent. The paired farm-mean blade-root DEL decreases by 0.82–2.24%, whereas the tower-base DEL increases by 0.76–2.78%, and the FairTen1 response generally increases by 0.88–2.92%. The farm-mean yaw-bearing response is mixed, ranging from a 1.15% reduction to a 4.32% increase. Turbine-level analysis reveals larger localized penalties, reaching approximately 10.4% for the yaw-bearing DEL and 12.8% for FairTen1. Spectral analysis associates the yaw-bearing response with yaw-induced aerodynamic and structural excitation, while the tower-base response is strongly influenced by low-frequency wave–platform dynamics. A complementary FLORIS sensitivity analysis demonstrates that the optimized aerodynamic benefit depends strongly on wind direction, spacing, wind speed, and turbulence intensity. For a Tampen-derived 11-turbine layout, resource weighting over the modeled 4–13ms−1 interval produces an annual energy-contribution increase of 3.653GWhyear−1, or 0.921%. These results provide numerical evidence that static wake steering can retain a positive power benefit in a coupled floating wind-farm environment, but controller assessment must include turbine- and component-specific dynamic loads rather than farm power alone.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-08-21
DOI
https://doi.org/10.3390/en19163938
Primary Topic
Wind Energy Research and Development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power and Fatigue–Load Assessment of Static Wake Steering in a Floating Wind Farm with 15 MW Turbines

Marco Belloli, Sara Muggiasca, Alessandro Fontanella, Federico Bellini et al.
Energies
Wind Energy Research and Development
article

Power and Fatigue–Load Assessment of Static Wake Steering in a Floating Wind Farm with 15 MW Turbines

Marco Belloli, Sara Muggiasca, Alessandro Fontanella, Federico Bellini, Majid Ebrahimi
article en

Abstract

Static wake steering can increase wind-farm power production, but its application to floating offshore wind farms requires assessment of the coupled wake, platform, structural, and station-keeping response. This study evaluates whether power-maximizing static yaw setpoints identified using the steady, control-oriented FLORIS model retain their benefit when transferred without re-optimization to a coupled FAST.Farm floating wind-farm model. The reference farm comprises four IEA Wind 15 MW turbines mounted on VolturnUS-S semi-submersible platforms. Greedy and static wake-steering operations are compared at three below-rated wind speeds, three sea states, and five matched turbulent-inflow realizations, resulting in 90 farm-level FAST.Farm simulations. Wake behavior is characterized through wake-center deflection, meandering, and velocity-deficit profiles, while turbine and mooring fatigue responses are evaluated using paired damage-equivalent-load statistics. Static wake steering increases mean farm power under all nine investigated wind–wave conditions. The gains are approximately 5.1–5.2% at 7ms−1, 5.0–5.1% at 8ms−1, and 4.0–4.2% at 9ms−1, with all paired 95% confidence intervals remaining above zero. The gain results from a power redistribution in which the intentionally yawed upstream turbine incurs a local loss that is exceeded by the combined recovery of the downstream turbines. The fatigue response is strongly component- and turbine-dependent. The paired farm-mean blade-root DEL decreases by 0.82–2.24%, whereas the tower-base DEL increases by 0.76–2.78%, and the FairTen1 response generally increases by 0.88–2.92%. The farm-mean yaw-bearing response is mixed, ranging from a 1.15% reduction to a 4.32% increase. Turbine-level analysis reveals larger localized penalties, reaching approximately 10.4% for the yaw-bearing DEL and 12.8% for FairTen1. Spectral analysis associates the yaw-bearing response with yaw-induced aerodynamic and structural excitation, while the tower-base response is strongly influenced by low-frequency wave–platform dynamics. A complementary FLORIS sensitivity analysis demonstrates that the optimized aerodynamic benefit depends strongly on wind direction, spacing, wind speed, and turbulence intensity. For a Tampen-derived 11-turbine layout, resource weighting over the modeled 4–13ms−1 interval produces an annual energy-contribution increase of 3.653GWhyear−1, or 0.921%. These results provide numerical evidence that static wake steering can retain a positive power benefit in a coupled floating wind-farm environment, but controller assessment must include turbine- and component-specific dynamic loads rather than farm power alone.

EnergiesVol. 19(16)
Politecnico di Milano (IT)
Affordable and clean energy
Openalex Percentile: Top 6%
Wind Energy Research and Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.