Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings

The transition to near-zero-energy buildings requires advanced envelopes to mitigate winter thermal losses and the “cold-pane” effect inherent to passive highly glazed façades. This study empirically evaluates an active triple-glazed unit with an integrated flexible heating foil to enhance thermal comfort. A dual-zone climatic chamber simulated severe sub-zero conditions down to −25 °C, utilizing high-resolution thermography, heat-flux sensor arrays, and Fanger’s criteria to quantify conjugate heat transfer and local discomfort. The results indicate that passive operation at −25 °C depresses inner surface temperatures, yielding severe perimeter dissatisfaction (predicted percentage of dissatisfied, PPD > 20%) and restricting the permissible window-to-wall ratio (WWR) to 22.7% to meet Category A comfort standards. Conversely, activating the heating setpoint to 40 °C establishes a near-adiabatic thermal barrier that neutralizes radiant asymmetry, suppresses convective downdraughts, and restores microclimatic stability (PPD < 10%). In conclusion, dynamic electro-thermal modulation effectively eliminates the perimeter cold sink, theoretically permitting up to a 100% WWR ceiling and relaxing the restrictive architectural constraints of conventional passive glazing under extreme winter conditions.

Authors

Publication Details

Journal
Energies
Published
2026-11-02
DOI
https://doi.org/10.3390/en19215235
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings

Hanna Koshlak
2 links
Energies
Building Energy and Comfort Optimization
article

Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings

Hanna Koshlak
article en

Abstract

The transition to near-zero-energy buildings requires advanced envelopes to mitigate winter thermal losses and the “cold-pane” effect inherent to passive highly glazed façades. This study empirically evaluates an active triple-glazed unit with an integrated flexible heating foil to enhance thermal comfort. A dual-zone climatic chamber simulated severe sub-zero conditions down to −25 °C, utilizing high-resolution thermography, heat-flux sensor arrays, and Fanger’s criteria to quantify conjugate heat transfer and local discomfort. The results indicate that passive operation at −25 °C depresses inner surface temperatures, yielding severe perimeter dissatisfaction (predicted percentage of dissatisfied, PPD > 20%) and restricting the permissible window-to-wall ratio (WWR) to 22.7% to meet Category A comfort standards. Conversely, activating the heating setpoint to 40 °C establishes a near-adiabatic thermal barrier that neutralizes radiant asymmetry, suppresses convective downdraughts, and restores microclimatic stability (PPD < 10%). In conclusion, dynamic electro-thermal modulation effectively eliminates the perimeter cold sink, theoretically permitting up to a 100% WWR ceiling and relaxing the restrictive architectural constraints of conventional passive glazing under extreme winter conditions.

EnergiesVol. 19(21)
Climate action, Sustainable cities and communities, Affordable and clean energy
Openalex Percentile: Top 48%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings — Hanna Koshlak · Energies (2026) | TGRS Research Map | TGRS