Perception and accuracy of an AI-based contactless wellness screening system in dental setting; a cross-sectional study

This study evaluates the reliability and participants' responses to a contactless artificial intelligence (AI) device powered by Remote Photoplethysmography (rPPG) technology for screening vital signs. The contactless AI-based device was compared with automated devices and the manual method as part of its validation for potential healthcare screening applications in dental clinics. A survey was conducted to assess the participants' perception. The Bland-Altman analysis was performed to assess agreement between methods. A total of 499 patients were recruited for this study. There were no significant differences between the contactless AI-based device system and automated or manual measurements for respiratory rate and oxygen saturation (p > 0.05). Significant differences were observed in heart rate, and systolic and diastolic blood pressure compared with the automated device (p < 0.05). Bland-Altman analysis revealed wide limits of agreement for blood pressure (± 30 mmHg for SBP, ± 20 mmHg for DBP) with proportional bias, indicating that BP measurement requires substantial algorithmic refinement before clinical implementation. Respiratory rate and oxygen saturation demonstrated excellent agreement with reference methods. Participants demonstrated high acceptance and positive perceptions of the AI-based system (all mean scores > 4.0) on a 5-point Likert scale. Participants also perceived that people and patients were generally optimistic about the potential of a contactless AI-based device used in dentistry. This study demonstrates that contactless rPPG technology shows validated clinical accuracy for respiratory rate and oxygen saturation monitoring in dental settings. However, blood pressure measurement algorithms require substantial refinement and further validation before clinical deployment. (250 words).

Authors

Institutions

Publication Details

Journal
The Saudi Dental Journal
Published
2026-08-21
DOI
https://doi.org/10.1007/s44445-026-00222-3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perception and accuracy of an AI-based contactless wellness screening system in dental setting; a cross-sectional study

Abdul Aziz, Normaliza Ab Malik, MOHAMED HISHAM MOHAMED JALI, Nur Faraheen Abdul Rahman et al.
The Saudi Dental Journal
Non-Invasive Vital Sign Monitoring
article

Perception and accuracy of an AI-based contactless wellness screening system in dental setting; a cross-sectional study

Abdul Aziz, Normaliza Ab Malik, MOHAMED HISHAM MOHAMED JALI, Nur Faraheen Abdul Rahman, Juliza Jamaludin, Muneer Gohar Babar
article en

Abstract

This study evaluates the reliability and participants' responses to a contactless artificial intelligence (AI) device powered by Remote Photoplethysmography (rPPG) technology for screening vital signs. The contactless AI-based device was compared with automated devices and the manual method as part of its validation for potential healthcare screening applications in dental clinics. A survey was conducted to assess the participants' perception. The Bland-Altman analysis was performed to assess agreement between methods. A total of 499 patients were recruited for this study. There were no significant differences between the contactless AI-based device system and automated or manual measurements for respiratory rate and oxygen saturation (p > 0.05). Significant differences were observed in heart rate, and systolic and diastolic blood pressure compared with the automated device (p < 0.05). Bland-Altman analysis revealed wide limits of agreement for blood pressure (± 30 mmHg for SBP, ± 20 mmHg for DBP) with proportional bias, indicating that BP measurement requires substantial algorithmic refinement before clinical implementation. Respiratory rate and oxygen saturation demonstrated excellent agreement with reference methods. Participants demonstrated high acceptance and positive perceptions of the AI-based system (all mean scores > 4.0) on a 5-point Likert scale. Participants also perceived that people and patients were generally optimistic about the potential of a contactless AI-based device used in dentistry. This study demonstrates that contactless rPPG technology shows validated clinical accuracy for respiratory rate and oxygen saturation monitoring in dental settings. However, blood pressure measurement algorithms require substantial refinement and further validation before clinical deployment. (250 words).

The Saudi Dental JournalVol. 38(9)
Universiti Sains Islam Malaysia (MY), IMU University (MY)
Universiti Sains Islam Malaysia
Openalex Percentile: Top 19%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.