Optimized PI Control of a PV-STATCOM for Power Oscillation Damping in Grid-Connected Photovoltaic Systems

This paper presents an optimized control strategy that enables a grid-connected photovoltaic (PV) system to operate as a static synchronous compensator (PV-STATCOM) to damp power oscillations in the transmission system, using an arithmetic optimization algorithm (AOA). The key contribution of this work is a synchronized, AOA-optimized multi-mode switching approach that includes standard PV operation, Full STATCOM, and Partial STATCOM with ramp-rate recovery, rather than relying solely on PI-gain adjustment. This is accomplished across the complete pre-fault, fault, and post-fault cycle. Under the proposed strategy, the PV system temporarily curtails its real power output when power oscillations arise following a system disturbance, thereby releasing the full inverter capacity for STATCOM operation and, hence, for oscillation damping. Once the oscillations are damped, the PV system ramps its real power back to the pre-disturbance level; at night, the inverter’s full capacity remains available for damping oscillations. The control scheme is implemented with a set of proportional–integral (PI) controllers whose parameters are tuned with the AOA, and its performance is benchmarked against tuning with the cuckoo search (CS) algorithm. Simulation results demonstrate that the AOA-tuned PV-STATCOM significantly improves damping, reduces oscillation amplitudes, maintains the point-of-common-coupling voltage within the low-voltage ride-through envelope, and keeps the system frequency within grid-code limits, thereby ensuring stable grid operation. Compared to a CS-tuned benchmark, the AOA-tuned design keeps the frequency continuously within the grid code band, settles at nominal 50 Hz, and reduces the maximum voltage overshoot from 20% to 15%.

Authors

Institutions

Publication Details

Journal
Algorithms
Published
2026-08-21
DOI
https://doi.org/10.3390/a19080702
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized PI Control of a PV-STATCOM for Power Oscillation Damping in Grid-Connected Photovoltaic Systems

Mohamed I. Mosaad
Algorithms
Microgrid Control and Optimization
article

Optimized PI Control of a PV-STATCOM for Power Oscillation Damping in Grid-Connected Photovoltaic Systems

Mohamed I. Mosaad
article en

Abstract

This paper presents an optimized control strategy that enables a grid-connected photovoltaic (PV) system to operate as a static synchronous compensator (PV-STATCOM) to damp power oscillations in the transmission system, using an arithmetic optimization algorithm (AOA). The key contribution of this work is a synchronized, AOA-optimized multi-mode switching approach that includes standard PV operation, Full STATCOM, and Partial STATCOM with ramp-rate recovery, rather than relying solely on PI-gain adjustment. This is accomplished across the complete pre-fault, fault, and post-fault cycle. Under the proposed strategy, the PV system temporarily curtails its real power output when power oscillations arise following a system disturbance, thereby releasing the full inverter capacity for STATCOM operation and, hence, for oscillation damping. Once the oscillations are damped, the PV system ramps its real power back to the pre-disturbance level; at night, the inverter’s full capacity remains available for damping oscillations. The control scheme is implemented with a set of proportional–integral (PI) controllers whose parameters are tuned with the AOA, and its performance is benchmarked against tuning with the cuckoo search (CS) algorithm. Simulation results demonstrate that the AOA-tuned PV-STATCOM significantly improves damping, reduces oscillation amplitudes, maintains the point-of-common-coupling voltage within the low-voltage ride-through envelope, and keeps the system frequency within grid-code limits, thereby ensuring stable grid operation. Compared to a CS-tuned benchmark, the AOA-tuned design keeps the frequency continuously within the grid code band, settles at nominal 50 Hz, and reduces the maximum voltage overshoot from 20% to 15%.

AlgorithmsVol. 19(8)
Yanbu University College (SA), Royal Commission for Jubail and Yanbu (SA), Royal Commission Medical Center (SA)
Affordable and clean energy
Openalex Percentile: Top 13%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimized PI Control of a PV-STATCOM for Power Oscillation Damping in Grid-Connected Photovoltaic Systems — Mohamed I. Mosaad · Algorithms (2026) | TGRS Research Map | TGRS