Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

PURPOSE: To evaluate the effects of scanner type and prosthesis design-luting protocol combinations on the passive fit of interim implant-supported complete-arch fixed dental prostheses (ISCFDPs) fabricated using a non-calibrated splinting grammetry system (OptiSplint). The null hypothesis was that scanner type and prosthesis design-luting protocol combinations would not affect the passive fit of interim ISCFDPs. MATERIALS AND METHODS: This in vitro 2 × 3 factorial study utilized a maxillary edentulous FP-3 master cast with 4 multiunit abutment (MUA) analogs. Extraoral scans of the OptiSplint assembly were obtained using either an intraoral scanner (IOS-OptiSplint) or a laboratory scanner (Lab-OptiSplint). Each scanning method was combined with each of the three prosthesis design-luting protocol combinations: (1) Ti-base with freehand cementation, (2) Ti-base cementation on a verification cast, and (3) Direct-to-MUA design, resulting in six experimental groups (n = 10 per group; N = 60). All prostheses were milled from pre-polymerized polymethylmethacrylate (PMMA) pucks using a five-axis milling unit. All PMMA ISCFDPs were evaluated for passive fit on the master cast using the screw-resistance test by two calibrated examiners, with discrepancies resolved by a third. Misfit was determined when incomplete seating or abnormal resistance was detected during sequential screw tightening. Inter-examiner reliability was assessed using Cohen's kappa, and misfit rates were compared via Fisher's exact tests (α = 0.05). RESULTS: Inter-examiner agreement was excellent (98%; κ = 0.95). Laboratory scanning achieved complete passive fit across all three prosthesis design-luting protocol combinations. With the IOS workflow, Ti-base on Cast demonstrated 0% misfit, Ti-base Freehand exhibited 30% misfit, and Direct-to-MUA demonstrated 100% misfit. Group 3 exhibited a significantly higher misfit frequency than all other groups (p < 0.001), whereas no other pairwise comparisons were significant. CONCLUSION: Laboratory scanning of a non-calibrated splinting grammetry system was associated with consistently complete passive fit across all groups. It may provide a predictable approach for achieving passive fit in complete-arch interim prostheses. Extraoral scanning with an intraoral scanner yielded variable results, underscoring the value of verification-cast cementation when using Ti-bases. Within the limitations of this study, the results suggest that Direct-to-MUA workflows may require laboratory-based scanning when using the evaluated systems.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-08-21
DOI
https://doi.org/10.1111/jopr.70218
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

Wei‐Shao Lin, Toshiki Nagai, Daizo Ishiguro, M S Omar
Journal of Prosthodontics
Dental materials and restorations
article

Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

Wei‐Shao Lin, Toshiki Nagai, Daizo Ishiguro, M S Omar
article en

Abstract

PURPOSE: To evaluate the effects of scanner type and prosthesis design-luting protocol combinations on the passive fit of interim implant-supported complete-arch fixed dental prostheses (ISCFDPs) fabricated using a non-calibrated splinting grammetry system (OptiSplint). The null hypothesis was that scanner type and prosthesis design-luting protocol combinations would not affect the passive fit of interim ISCFDPs. MATERIALS AND METHODS: This in vitro 2 × 3 factorial study utilized a maxillary edentulous FP-3 master cast with 4 multiunit abutment (MUA) analogs. Extraoral scans of the OptiSplint assembly were obtained using either an intraoral scanner (IOS-OptiSplint) or a laboratory scanner (Lab-OptiSplint). Each scanning method was combined with each of the three prosthesis design-luting protocol combinations: (1) Ti-base with freehand cementation, (2) Ti-base cementation on a verification cast, and (3) Direct-to-MUA design, resulting in six experimental groups (n = 10 per group; N = 60). All prostheses were milled from pre-polymerized polymethylmethacrylate (PMMA) pucks using a five-axis milling unit. All PMMA ISCFDPs were evaluated for passive fit on the master cast using the screw-resistance test by two calibrated examiners, with discrepancies resolved by a third. Misfit was determined when incomplete seating or abnormal resistance was detected during sequential screw tightening. Inter-examiner reliability was assessed using Cohen's kappa, and misfit rates were compared via Fisher's exact tests (α = 0.05). RESULTS: Inter-examiner agreement was excellent (98%; κ = 0.95). Laboratory scanning achieved complete passive fit across all three prosthesis design-luting protocol combinations. With the IOS workflow, Ti-base on Cast demonstrated 0% misfit, Ti-base Freehand exhibited 30% misfit, and Direct-to-MUA demonstrated 100% misfit. Group 3 exhibited a significantly higher misfit frequency than all other groups (p < 0.001), whereas no other pairwise comparisons were significant. CONCLUSION: Laboratory scanning of a non-calibrated splinting grammetry system was associated with consistently complete passive fit across all groups. It may provide a predictable approach for achieving passive fit in complete-arch interim prostheses. Extraoral scanning with an intraoral scanner yielded variable results, underscoring the value of verification-cast cementation when using Ti-bases. Within the limitations of this study, the results suggest that Direct-to-MUA workflows may require laboratory-based scanning when using the evaluated systems.

Journal of Prosthodontics
Indiana University – Purdue University Indianapolis (US)
Openalex Percentile: Top 8%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.