Comparison of endothelin-1 levels in human plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Endothelin-1 (ET-1) antagonists are increasingly being approved for new treatments for cardiovascular disease, where elevated ET-1 levels contribute to increased vasoconstriction. Further therapeutic targets, including coronary artery disease, are under investigation. The Olink Explore 3072 Proximity Extension Assay platform enables multiplexed high throughput measurement of ~3000 plasma proteins, from minimal (≤6µl) sample volumes. However, it is not known if the two oligonucleotide‑tagged antibodies raised against preproET-1₁-₂₁₂, used in this Olink assay, specifically measure biologically active ET-1 or the other inactive EDN1-encoded peptides, also secreted by human endothelial cells. Paired plasma samples from 29 patients with coronary artery disease were obtained, using a specialised intra-coronary sampling catheter, designed to obtain site specific biochemical information from within coronary arteries. We compared ET-1 concentrations measured with an ET-1 specific ELISA, demonstrated to have no cross reactivity with other EDN1-encoded peptides versus values obtained using Olink Explore platform. Olink-measured ET-1 correlated significantly with ELISA-derived ET-1 levels (r=0.53, p=0.003), and Olink values predicted ELISA results. Olink ET-1 concentrations also correlated with ETB receptor levels (r=0.40, p< 0.05). These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET-1, supporting its use as a biomarker tool in clinical and translational studies.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Physiology and Pharmacology
Published
2026-08-21
DOI
https://doi.org/10.1139/cjpp-2026-0112
Primary Topic
Nitric Oxide and Endothelin Effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of endothelin-1 levels in human plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Rhoda E. Kuc, Diane Proudfoot, George Abraham, Anthony P. Davenport et al.
Canadian Journal of Physiology and Pharmacology
Nitric Oxide and Endothelin Effects
article

Comparison of endothelin-1 levels in human plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Rhoda E. Kuc, Diane Proudfoot, George Abraham, Anthony P. Davenport, Stephen P. Hoole, Majid Anwar, Janet Maguire, Catherine Bullock
article en

Abstract

Endothelin-1 (ET-1) antagonists are increasingly being approved for new treatments for cardiovascular disease, where elevated ET-1 levels contribute to increased vasoconstriction. Further therapeutic targets, including coronary artery disease, are under investigation. The Olink Explore 3072 Proximity Extension Assay platform enables multiplexed high throughput measurement of ~3000 plasma proteins, from minimal (≤6µl) sample volumes. However, it is not known if the two oligonucleotide‑tagged antibodies raised against preproET-1₁-₂₁₂, used in this Olink assay, specifically measure biologically active ET-1 or the other inactive EDN1-encoded peptides, also secreted by human endothelial cells. Paired plasma samples from 29 patients with coronary artery disease were obtained, using a specialised intra-coronary sampling catheter, designed to obtain site specific biochemical information from within coronary arteries. We compared ET-1 concentrations measured with an ET-1 specific ELISA, demonstrated to have no cross reactivity with other EDN1-encoded peptides versus values obtained using Olink Explore platform. Olink-measured ET-1 correlated significantly with ELISA-derived ET-1 levels (r=0.53, p=0.003), and Olink values predicted ELISA results. Olink ET-1 concentrations also correlated with ETB receptor levels (r=0.40, p< 0.05). These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET-1, supporting its use as a biomarker tool in clinical and translational studies.

Canadian Journal of Physiology and Pharmacology
Babraham Institute (GB), Royal Papworth Hospital (GB), OSE Immunotherapeutics (France) (FR), Papworth Hospital NHS Foundation Trust (GB)
Good health and well-being
Openalex Percentile: Top 11%
Nitric Oxide and Endothelin Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.