Influence of T-Stub Stiffness Configuration on the Cyclic Performance and Damage Evolution of Blind-Bolted Beam-to-Square Hollow Section Column Connections

Four full-scale exterior beam-to-column connections comprising H-section beams and square hollow-section (SHS) columns were tested under low-cycle reversed loading to investigate two engineering-oriented T-stub section configurations and the effects of the presence or absence of triangular stiffeners. Failure modes, moment–rotation response, stiffness degradation, energy dissipation, and cumulative damage were evaluated, together with nonlinear finite element simulations and a modified Park–Ang damage assessment. All specimens progressed from bolt-hole slip through plastic deformation to localized fracture. In the unstiffened connections, damage concentrated near the T-stub flange-to-web junction; stiffeners redistributed critical demand toward the stiffener welds, adjacent T-stub webs, and SHS column walls. The maximum differences in initial rotational stiffness relative to J1A were 15.69% and 15.07% in the positive and negative loading directions, indicating that the elastic-stage response reflected the combined deformability of the T-stub, blind-bolt assembly, and column wall. The maximum increases in yield moment, peak-resistance moment, and ductility coefficient were 20.59%, 43.71%, and 45.91%, respectively. Complete-history energy dissipation varied non-monotonically across the tested configurations. The finite element model reproduced the global and local responses, while the damage-index results showed overall correspondence with the observed failure progression. The findings emphasize stiffness compatibility and rational distribution of plastic demand rather than maximum local stiffness.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-08-20
DOI
https://doi.org/10.3390/buildings16163318
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of T-Stub Stiffness Configuration on the Cyclic Performance and Damage Evolution of Blind-Bolted Beam-to-Square Hollow Section Column Connections

Xinwu Wang, Zhanjing Wu, Gaofei Huang, Yifei Chen et al.
Buildings
Structural Load-Bearing Analysis
article

Influence of T-Stub Stiffness Configuration on the Cyclic Performance and Damage Evolution of Blind-Bolted Beam-to-Square Hollow Section Column Connections

Xinwu Wang, Zhanjing Wu, Gaofei Huang, Yifei Chen, Jia Fan, Xin Bu
article en

Abstract

Four full-scale exterior beam-to-column connections comprising H-section beams and square hollow-section (SHS) columns were tested under low-cycle reversed loading to investigate two engineering-oriented T-stub section configurations and the effects of the presence or absence of triangular stiffeners. Failure modes, moment–rotation response, stiffness degradation, energy dissipation, and cumulative damage were evaluated, together with nonlinear finite element simulations and a modified Park–Ang damage assessment. All specimens progressed from bolt-hole slip through plastic deformation to localized fracture. In the unstiffened connections, damage concentrated near the T-stub flange-to-web junction; stiffeners redistributed critical demand toward the stiffener welds, adjacent T-stub webs, and SHS column walls. The maximum differences in initial rotational stiffness relative to J1A were 15.69% and 15.07% in the positive and negative loading directions, indicating that the elastic-stage response reflected the combined deformability of the T-stub, blind-bolt assembly, and column wall. The maximum increases in yield moment, peak-resistance moment, and ductility coefficient were 20.59%, 43.71%, and 45.91%, respectively. Complete-history energy dissipation varied non-monotonically across the tested configurations. The finite element model reproduced the global and local responses, while the damage-index results showed overall correspondence with the observed failure progression. The findings emphasize stiffness compatibility and rational distribution of plastic demand rather than maximum local stiffness.

BuildingsVol. 16(16)
SCIVIC Engineering Corporation (China) (CN), Luoyang Institute of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 15%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.