Contactless ECG Reconstruction from Millimeter-Wave Radar Signals Using a CNN-BiLSTM Network

To investigate the feasibility of reconstructing electrocardiogram (ECG) waveforms from non-contact millimeter-wave radar measurements, a radar-based ECG reconstruction method using a CNN-BiLSTM network is presented. A synchronous acquisition platform integrating a millimeter-wave radar and a BIOPAC physiological signal acquisition system was established to collect chest-wall vibration signals and reference ECG signals. A multi-channel cross-correlation-based channel selection and temporal alignment procedure was employed to construct paired radar–ECG samples. The radar chest-wall vibration signals were filtered using an 8–30 Hz band-pass filter and then fed into the CNN-BiLSTM model, while a joint time–frequency loss function was introduced to constrain ECG reconstruction. On the self-built vital sign dataset, the reconstructed ECG achieved a correlation coefficient of 0.5631 with the reference ECG, while the mean absolute errors of heart rate and R–R interval were 1.00 BPM and 10.02 ms, respectively. These results suggest that the reconstructed signals preserve basic heartbeat timing and overall rhythm-related information, although the waveform-level agreement varies among samples and does not yet demonstrate consistent recovery of fine-grained ECG morphology. Evaluation on a public dataset further showed condition-dependent reconstruction performance under Resting, Apnea, and Valsalva conditions. Published MultiRes-LinkNet values were included only as contextual numerical references because the baseline was not reimplemented within the same experimental pipeline. Overall, the results provide preliminary evidence for the feasibility of contactless ECG reconstruction from millimeter-wave radar signals and suggest its potential value for radar-based vital sign monitoring.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-08-20
DOI
https://doi.org/10.3390/electronics15163732
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contactless ECG Reconstruction from Millimeter-Wave Radar Signals Using a CNN-BiLSTM Network

Qida Yu, Xinnan Zhao, Xiaoyan Zhou, Bo Ni et al.
Electronics
Non-Invasive Vital Sign Monitoring
article

Contactless ECG Reconstruction from Millimeter-Wave Radar Signals Using a CNN-BiLSTM Network

Qida Yu, Xinnan Zhao, Xiaoyan Zhou, Bo Ni, Mingda Liu
article en

Abstract

To investigate the feasibility of reconstructing electrocardiogram (ECG) waveforms from non-contact millimeter-wave radar measurements, a radar-based ECG reconstruction method using a CNN-BiLSTM network is presented. A synchronous acquisition platform integrating a millimeter-wave radar and a BIOPAC physiological signal acquisition system was established to collect chest-wall vibration signals and reference ECG signals. A multi-channel cross-correlation-based channel selection and temporal alignment procedure was employed to construct paired radar–ECG samples. The radar chest-wall vibration signals were filtered using an 8–30 Hz band-pass filter and then fed into the CNN-BiLSTM model, while a joint time–frequency loss function was introduced to constrain ECG reconstruction. On the self-built vital sign dataset, the reconstructed ECG achieved a correlation coefficient of 0.5631 with the reference ECG, while the mean absolute errors of heart rate and R–R interval were 1.00 BPM and 10.02 ms, respectively. These results suggest that the reconstructed signals preserve basic heartbeat timing and overall rhythm-related information, although the waveform-level agreement varies among samples and does not yet demonstrate consistent recovery of fine-grained ECG morphology. Evaluation on a public dataset further showed condition-dependent reconstruction performance under Resting, Apnea, and Valsalva conditions. Published MultiRes-LinkNet values were included only as contextual numerical references because the baseline was not reimplemented within the same experimental pipeline. Overall, the results provide preliminary evidence for the feasibility of contactless ECG reconstruction from millimeter-wave radar signals and suggest its potential value for radar-based vital sign monitoring.

ElectronicsVol. 15(16)
Nanjing University of Information Science and Technology (CN), Southeast University (CN)
Openalex Percentile: Top 18%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Contactless ECG Reconstruction from Millimeter-Wave Radar Signals Using a CNN-BiLSTM Network — Qida Yu, Xinnan Zhao, et al. · Electronics (2026) | TGRS Research Map | TGRS