Initial Visual and Refractive Outcomes of Ray-Tracing-Guided LASIK (Wavelight Plus) Versus KLEx (SMILE Pro)

INTRODUCTION: This study evaluates visual and refractive outcomes of our initial experience using ray-tracing-guided Wavelight Plus (WLP) LASIK and SMILE Pro KLEx carried out by one surgeon at a single center. METHODS: A retrospective, non-randomized study was conducted at one refractive surgery center. Patients undergoing WLP or SMILE Pro with at least 1 month of postoperative follow-up were included. Outcomes were assessed at 1 and 3 months and included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), safety and efficacy indices, and vector analysis of astigmatism. Additionally, a comparison with wavefront-optimized (WFO) LASIK, an established procedure with a well-refined nomogram at the study center, was provided as an internal benchmark. RESULTS: A total of 160 eyes from 93 patients were analyzed, including 50 eyes treated with WLP, 55 with SMILE Pro, and 55 with WFO. WLP demonstrated significantly better UDVA than SMILE Pro at both 1 month (p < 0.001) and 3 months (p = 0.033) and was more likely to achieve a UDVA of 20/20. Residual astigmatism was significantly lower in the WLP group than in both the WFO and SMILE Pro groups at 1 and 3 months (all p < 0.001). Vector analysis showed a correction index of 1.13 for SMILE Pro, 1.11 for WFO, and 1.08 for WLP at 3 months. CONCLUSIONS: In our initial experience with the WLP and SMILE Pro platforms, WLP achieved better UDVA and more precise astigmatic correction compared with SMILE Pro. Additionally, WLP, without the use of a nomogram, had comparable safety and efficacy outcomes to WFO. Based on our initial experience at one center, astigmatic correction appears to be a limiting factor for KLEx platforms in achieving outcomes similar to modern LASIK platforms.

Authors

Institutions

Publication Details

Journal
Ophthalmology and Therapy
Published
2026-08-20
DOI
https://doi.org/10.1007/s40123-026-01475-1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial Visual and Refractive Outcomes of Ray-Tracing-Guided LASIK (Wavelight Plus) Versus KLEx (SMILE Pro)

Phillip C. Hoopes, Jonathan C. Davis, Hanna Pawlowski, Majid Moshirfar et al.
Ophthalmology and Therapy
Corneal surgery and disorders
article

Initial Visual and Refractive Outcomes of Ray-Tracing-Guided LASIK (Wavelight Plus) Versus KLEx (SMILE Pro)

Phillip C. Hoopes, Jonathan C. Davis, Hanna Pawlowski, Majid Moshirfar, Mina M. Sitto, Calisa G. Lee-Choi, Cole S. Elsner, Sanjana Molleti, Randle M. Uyeda
article en

Abstract

INTRODUCTION: This study evaluates visual and refractive outcomes of our initial experience using ray-tracing-guided Wavelight Plus (WLP) LASIK and SMILE Pro KLEx carried out by one surgeon at a single center. METHODS: A retrospective, non-randomized study was conducted at one refractive surgery center. Patients undergoing WLP or SMILE Pro with at least 1 month of postoperative follow-up were included. Outcomes were assessed at 1 and 3 months and included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), safety and efficacy indices, and vector analysis of astigmatism. Additionally, a comparison with wavefront-optimized (WFO) LASIK, an established procedure with a well-refined nomogram at the study center, was provided as an internal benchmark. RESULTS: A total of 160 eyes from 93 patients were analyzed, including 50 eyes treated with WLP, 55 with SMILE Pro, and 55 with WFO. WLP demonstrated significantly better UDVA than SMILE Pro at both 1 month (p < 0.001) and 3 months (p = 0.033) and was more likely to achieve a UDVA of 20/20. Residual astigmatism was significantly lower in the WLP group than in both the WFO and SMILE Pro groups at 1 and 3 months (all p < 0.001). Vector analysis showed a correction index of 1.13 for SMILE Pro, 1.11 for WFO, and 1.08 for WLP at 3 months. CONCLUSIONS: In our initial experience with the WLP and SMILE Pro platforms, WLP achieved better UDVA and more precise astigmatic correction compared with SMILE Pro. Additionally, WLP, without the use of a nomogram, had comparable safety and efficacy outcomes to WFO. Based on our initial experience at one center, astigmatic correction appears to be a limiting factor for KLEx platforms in achieving outcomes similar to modern LASIK platforms.

Ophthalmology and Therapy
University of Minnesota (US), University of Arizona (US), University of South Carolina (US), University of Phoenix (US), University of Utah (US), Minnesota Lions Eye Bank (US), Hoopes Vision (US)
Openalex Percentile: Top 10%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.