Development and Internal Validation of a Multivariable Prediction Model for Complications After External Cephalic Version in Singleton Term Pregnancies

Objectives: This study aimed to describe the incidence and clinical spectrum of external cephalic versión (ECV)-related complications, to evaluate pre-procedural predictors of their occurrence, and to develop and internally validate a prediction model for ECV-related complications. Methods: This single-center cohort study included ECV procedures performed in singleton pregnancies with non-cephalic presentation at term between January 2014 and December 2025. All procedures followed a standardized protocol, including tocolysis and either deep sedation or spinal anesthesia. ECV-related complications were defined as maternal or fetal adverse events occurring during the procedure or within 24 h after ECV. A prespecified multivariable logistic regression model was developed using clinically relevant pre-procedural variables. Model discrimination was assessed using the area under the receiver operating characteristic curve (AUC), and internal validation was performed by bootstrap resampling. Results: A total of 1050 ECV procedures were included, of which 733 (69.7%) were successful. Complication status was available for 1050 procedures, among which 113 ECV-related complications were recorded (10.8%). Complications were more frequent after failed than successful ECV (17.6% vs. 7.8%). The most frequent events were non-reassuring fetal heart rate patterns, major vaginal bleeding, spotting, and uterine contractions. Emergent cesarean delivery within 24 h occurred in 72 complication cases (63.7%). No neonatal deaths occurred among cases with ECV-related complications. In the final multivariable model, lower maternal body mass index (adjusted OR 0.92 per kg/m2), lower deepest vertical pocket (adjusted OR 0.69 per 10 mm), and breech rather than transverse lie (adjusted OR 0.24) were independently associated with ECV-related complications. Adding deepest vertical pocket significantly improved model discrimination from an AUC of 0.645 to 0.714. Bootstrap internal validation demonstrated limited optimism, with an optimism-corrected AUC of 0.699. Conclusions: ECV performed under a standardized protocol achieved a high success rate with an acceptable safety profile, although approximately one in ten procedures was associated with an ECV-related complication when broadly defined. Lower maternal BMI, reduced amniotic fluid volume, and breech presentation were the main pre-procedural predictors of complications. These findings may facilitate individualized counselling and procedural planning, although external validation is required before clinical implementation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-08-20
DOI
https://doi.org/10.3390/jcm15166443
Primary Topic
Maternal and Perinatal Health Interventions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Internal Validation of a Multivariable Prediction Model for Complications After External Cephalic Version in Singleton Term Pregnancies

Alberto Rafael Guijarro‐Campillo, Rosa María Gallego-Pozuelo, Javier Sánchez‐Romero, Romina Sol Liandro et al.
Journal of Clinical Medicine
Maternal and Perinatal Health Interventions
article

Development and Internal Validation of a Multivariable Prediction Model for Complications After External Cephalic Version in Singleton Term Pregnancies

Alberto Rafael Guijarro‐Campillo, Rosa María Gallego-Pozuelo, Javier Sánchez‐Romero, Romina Sol Liandro, Catalina de Paco-Matallana, Olivia Varó-Torrecillas, Miriam Isabel García-Pérez, Clara Cámara-Cases, Margarita González-Guillén, Inmaculada Concepción Delgado-Gonzálvez, Estrella Naranjo-Díaz
article en

Abstract

Objectives: This study aimed to describe the incidence and clinical spectrum of external cephalic versión (ECV)-related complications, to evaluate pre-procedural predictors of their occurrence, and to develop and internally validate a prediction model for ECV-related complications. Methods: This single-center cohort study included ECV procedures performed in singleton pregnancies with non-cephalic presentation at term between January 2014 and December 2025. All procedures followed a standardized protocol, including tocolysis and either deep sedation or spinal anesthesia. ECV-related complications were defined as maternal or fetal adverse events occurring during the procedure or within 24 h after ECV. A prespecified multivariable logistic regression model was developed using clinically relevant pre-procedural variables. Model discrimination was assessed using the area under the receiver operating characteristic curve (AUC), and internal validation was performed by bootstrap resampling. Results: A total of 1050 ECV procedures were included, of which 733 (69.7%) were successful. Complication status was available for 1050 procedures, among which 113 ECV-related complications were recorded (10.8%). Complications were more frequent after failed than successful ECV (17.6% vs. 7.8%). The most frequent events were non-reassuring fetal heart rate patterns, major vaginal bleeding, spotting, and uterine contractions. Emergent cesarean delivery within 24 h occurred in 72 complication cases (63.7%). No neonatal deaths occurred among cases with ECV-related complications. In the final multivariable model, lower maternal body mass index (adjusted OR 0.92 per kg/m2), lower deepest vertical pocket (adjusted OR 0.69 per 10 mm), and breech rather than transverse lie (adjusted OR 0.24) were independently associated with ECV-related complications. Adding deepest vertical pocket significantly improved model discrimination from an AUC of 0.645 to 0.714. Bootstrap internal validation demonstrated limited optimism, with an optimism-corrected AUC of 0.699. Conclusions: ECV performed under a standardized protocol achieved a high success rate with an acceptable safety profile, although approximately one in ten procedures was associated with an ECV-related complication when broadly defined. Lower maternal BMI, reduced amniotic fluid volume, and breech presentation were the main pre-procedural predictors of complications. These findings may facilitate individualized counselling and procedural planning, although external validation is required before clinical implementation.

Journal of Clinical MedicineVol. 15(16)
Instituto de Salud Carlos III (ES), Instituto Murciano de Investigación Biosanitaria (ES), Hospital Universitario Virgen de la Arrixaca (ES), Universidad de Murcia (ES)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Maternal and Perinatal Health Interventions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.