EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis

OBJECTIVES: To evaluate the agreement of a commercially available point-of-care FCoV RT-qPCR assay and external laboratories RT-qPCR testing in cats with effusive and non-effusive FIP, and in cats with other diseases presenting with similar clinical signs. METHODS: Client-owned cats suspected of FIP were enrolled with owner consent. Effusions and ultrasound-guided fine-needle aspirates (FNAs) from liver, spleen, or mesenteric lymph nodes were collected, split, and analysed using both a point-of-care RT-qPCR and an external laboratory RT-qPCR. FIP was diagnosed based on AAFP/EveryCat guidelines. Sensitivity and negative predictive values were calculated, agreement assessed with Cohen's kappa, paired differences tested with McNemar's test, and correlation of crossing point (Cp) values analysed using Pearson's coefficient and paired t-tests. RESULTS: One hundred cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% point-of-care, 92.3% external) and lower in FNAs (63.3-64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle). CONCLUSION AND RELEVANCE: The point-of-care FCoV RT-qPCR assay is a practical and reliable tool and shows very good agreement with external reference laboratory RT-qPCR testing. FNAs remain useful when effusions are unavailable but carry higher risk of false negatives likely due to low viral loads and heterogeneous distribution. Point-of-care testing offers rapid turnaround, supporting timely clinical decision-making, but results must be interpreted alongside clinical presentation and other diagnostics.

Authors

Institutions

Publication Details

Journal
Journal of Feline Medicine and Surgery
Published
2026-08-20
DOI
https://doi.org/10.1177/1098612x261483596
Primary Topic
Animal Virus Infections Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis

Erik Teske, Marieke Knies, Els M. Broens, Johanna Jackson-Onis et al.
Journal of Feline Medicine and Surgery
Animal Virus Infections Studies
article

EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis

Erik Teske, Marieke Knies, Els M. Broens, Johanna Jackson-Onis, Nikki Hofman
article en

Abstract

OBJECTIVES: To evaluate the agreement of a commercially available point-of-care FCoV RT-qPCR assay and external laboratories RT-qPCR testing in cats with effusive and non-effusive FIP, and in cats with other diseases presenting with similar clinical signs. METHODS: Client-owned cats suspected of FIP were enrolled with owner consent. Effusions and ultrasound-guided fine-needle aspirates (FNAs) from liver, spleen, or mesenteric lymph nodes were collected, split, and analysed using both a point-of-care RT-qPCR and an external laboratory RT-qPCR. FIP was diagnosed based on AAFP/EveryCat guidelines. Sensitivity and negative predictive values were calculated, agreement assessed with Cohen's kappa, paired differences tested with McNemar's test, and correlation of crossing point (Cp) values analysed using Pearson's coefficient and paired t-tests. RESULTS: One hundred cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% point-of-care, 92.3% external) and lower in FNAs (63.3-64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle). CONCLUSION AND RELEVANCE: The point-of-care FCoV RT-qPCR assay is a practical and reliable tool and shows very good agreement with external reference laboratory RT-qPCR testing. FNAs remain useful when effusions are unavailable but carry higher risk of false negatives likely due to low viral loads and heterogeneous distribution. Point-of-care testing offers rapid turnaround, supporting timely clinical decision-making, but results must be interpreted alongside clinical presentation and other diagnostics.

Journal of Feline Medicine and Surgery
Utrecht University (NL), GGD Haaglanden (NL), Medisch Centrum Haaglanden (NL)
Peace, Justice and strong institutions
Openalex Percentile: Top 12%
Animal Virus Infections Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.