Suppression of 40K-Induced background in gamma-ray spectrometry for food radioactivity analysis: A Monte Carlo study

Improving the sensitivity of gamma-ray spectrometry is crucial for food safety monitoring. However, naturally abundant 40 K in these foods generates significant continuous spectrum background that severely interferes with the detection of other key environmental radionuclides. This study conducted Monte Carlo simulations in Geant4 to systematically quantify the interference mechanism of 40 K in gamma-ray energy spectrum measurements. Simulations indicate that the continuous spectrum of bremsstrahlung radiation emitted by 40 K beta particles is the primary source of interference, leading to a significant increase in the background level. The optimized sample container structure proposed in this study reduces the 40 K background in the target energy region (e.g., the 210 Pb region) by approximately 57%, improving the detection sensitivity with a 17% reduction in the relative minimum detectable activity.

Authors

Institutions

Publication Details

Journal
Applied Radiation and Isotopes
Published
2026-08-20
DOI
https://doi.org/10.1016/j.apradiso.2026.112864
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suppression of 40K-Induced background in gamma-ray spectrometry for food radioactivity analysis: A Monte Carlo study

Heting Chen, Fei Tuo, Zeshu Li, Hongying Wang et al.
Applied Radiation and Isotopes
Radioactivity and Radon Measurements
article

Suppression of 40K-Induced background in gamma-ray spectrometry for food radioactivity analysis: A Monte Carlo study

Heting Chen, Fei Tuo, Zeshu Li, Hongying Wang, Baolu Yang, Shuying Kong, Zhenglin Ye, Weihao Qin, Xuan Zhang, Qiang Zhou
article en

Abstract

Improving the sensitivity of gamma-ray spectrometry is crucial for food safety monitoring. However, naturally abundant 40 K in these foods generates significant continuous spectrum background that severely interferes with the detection of other key environmental radionuclides. This study conducted Monte Carlo simulations in Geant4 to systematically quantify the interference mechanism of 40 K in gamma-ray energy spectrum measurements. Simulations indicate that the continuous spectrum of bremsstrahlung radiation emitted by 40 K beta particles is the primary source of interference, leading to a significant increase in the background level. The optimized sample container structure proposed in this study reduces the 40 K background in the target energy region (e.g., the 210 Pb region) by approximately 57%, improving the detection sensitivity with a 17% reduction in the relative minimum detectable activity.

Applied Radiation and IsotopesVol. 237
Chinese Center For Disease Control and Prevention (CN), National Institute for Radiological Protection (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 9%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.