Research on high voltage circuit breaker fault diagnosis using multi-strategy improved dung beetle algorithm optimized CNN-BiGRU-attention model

Accurate fault diagnosis of high-voltage circuit breakers is essential for improving power-system reliability. However, coil-current signals are often affected by environmental interference and random fluctuations in the measurement circuit, which may reduce diagnostic accuracy and lead to unstable recognition results. To address this problem, this paper proposes a fault diagnosis method based on opening and closing coil-current signals of high-voltage circuit breakers.First, an improved wavelet-threshold variational mode decomposition method is used to suppress noise while preserving fault-sensitive waveform characteristics. Then, extrema, temporal features, and waveform statistical features are extracted from the denoised signals. A CNN-BiGRU-Attention model is constructed to learn local waveform features and temporal dependencies. The model parameters are further optimized using a multi-strategy improved dung beetle optimization algorithm to improve parameter search performance and reduce the risk of local optima.Experiments were conducted on a physical ZN63–12 high-voltage vacuum circuit breaker platform under controlled laboratory fault-simulation conditions. The proposed method achieved an overall diagnostic accuracy of 96.5% across five operating states. The results indicate that the method can effectively distinguish normal operation, inter-turn short circuit, poor contact, overvoltage, and undervoltage conditions within the tested experimental scope. This study provides a potential data-driven approach for coil-current-based fault diagnosis of high-voltage circuit breakers, while further validation on additional breaker types and field operating conditions is still required.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-08-20
DOI
https://doi.org/10.1016/j.egyr.2026.109643
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on high voltage circuit breaker fault diagnosis using multi-strategy improved dung beetle algorithm optimized CNN-BiGRU-attention model

Yongchun Liang, Shang Liu, Fang Wang, Yuyang Zhao et al.
Energy Reports
Power System Reliability and Maintenance
article

Research on high voltage circuit breaker fault diagnosis using multi-strategy improved dung beetle algorithm optimized CNN-BiGRU-attention model

Yongchun Liang, Shang Liu, Fang Wang, Yuyang Zhao, Hexu Sun
article en

Abstract

Accurate fault diagnosis of high-voltage circuit breakers is essential for improving power-system reliability. However, coil-current signals are often affected by environmental interference and random fluctuations in the measurement circuit, which may reduce diagnostic accuracy and lead to unstable recognition results. To address this problem, this paper proposes a fault diagnosis method based on opening and closing coil-current signals of high-voltage circuit breakers.First, an improved wavelet-threshold variational mode decomposition method is used to suppress noise while preserving fault-sensitive waveform characteristics. Then, extrema, temporal features, and waveform statistical features are extracted from the denoised signals. A CNN-BiGRU-Attention model is constructed to learn local waveform features and temporal dependencies. The model parameters are further optimized using a multi-strategy improved dung beetle optimization algorithm to improve parameter search performance and reduce the risk of local optima.Experiments were conducted on a physical ZN63–12 high-voltage vacuum circuit breaker platform under controlled laboratory fault-simulation conditions. The proposed method achieved an overall diagnostic accuracy of 96.5% across five operating states. The results indicate that the method can effectively distinguish normal operation, inter-turn short circuit, poor contact, overvoltage, and undervoltage conditions within the tested experimental scope. This study provides a potential data-driven approach for coil-current-based fault diagnosis of high-voltage circuit breakers, while further validation on additional breaker types and field operating conditions is still required.

Energy ReportsVol. 16
State Grid Corporation of China (China) (CN), Hebei University of Science and Technology (CN), HBIS (China) (CN), Hebei Science and Technology Department (CN)
Openalex Percentile: Top 10%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.