Rapid phage susceptibility determination using a semi-automated bioluminescent ATP assay

ABSTRACT Antimicrobial resistance is a major threat to human health. Phage therapy is a promising alternative to antibiotics, yet routine diagnostic tools capable of rapidly determining phage susceptibility are lacking. Our goal was to develop a diagnostic tool providing easy-to-interpret in vitro phage activity results within a clinically relevant time frame. We developed a prototype based on bioluminescence emitted by adenosine triphosphate (ATP) release during phage-mediated bacterial lysis. Ten phages were tested against 20 clinical isolates of four species: Pseudomonas aeruginosa , Staphylococcus aureus , Escherichia coli , and Klebsiella pneumoniae . Overall concordance with double agar overlay (DAO) was fair (72%). The prototype showed high sensitivity (94.5%) at detecting weak killers and high specificity (87%) at identifying strong killer phages. Most discordances involved DAO weak killers classified as active by the prototype. Most of these discordant phage-bacteria couples produced a spot in the spot test, suggesting the assay may detect but not distinguish killing without replication from killing with replication. The method showed high repeatability and reproducibility. A few aberrant species specificity results highlighted the need for routine controls. Results from prospective urine samples were obtained within an average of 5 h. IMPORTANCE The lack of reproducible user-friendly phage susceptibility testing that can timely inform clinical decisions remains a major barrier to the routine clinical use of phages. We developed a high-throughput, semi-automated prototype that delivers easy-to-interpret phage susceptibility results for four bacterial species within 5 h in a “real-life” clinical flow. However, the correlation between in vitro lytic activity and clinical outcomes still needs to be established to meet regulatory requirements for in vitro diagnostic (IVD) medical devices.

Authors

Institutions

Publication Details

Journal
Microbiology Spectrum
Published
2026-08-20
DOI
https://doi.org/10.1128/spectrum.00782-26
Primary Topic
Bacteriophages and microbial interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid phage susceptibility determination using a semi-automated bioluminescent ATP assay

Johan Quintens, Marie Hallin, Olivier Vandenberg, Isabelle Tytgat et al.
Microbiology Spectrum
Bacteriophages and microbial interactions
article

Rapid phage susceptibility determination using a semi-automated bioluminescent ATP assay

Johan Quintens, Marie Hallin, Olivier Vandenberg, Isabelle Tytgat, Valéry Daubie, Bob Blasdel, Hafid Dahma, Houssein Chalhoub
article en

Abstract

ABSTRACT Antimicrobial resistance is a major threat to human health. Phage therapy is a promising alternative to antibiotics, yet routine diagnostic tools capable of rapidly determining phage susceptibility are lacking. Our goal was to develop a diagnostic tool providing easy-to-interpret in vitro phage activity results within a clinically relevant time frame. We developed a prototype based on bioluminescence emitted by adenosine triphosphate (ATP) release during phage-mediated bacterial lysis. Ten phages were tested against 20 clinical isolates of four species: Pseudomonas aeruginosa , Staphylococcus aureus , Escherichia coli , and Klebsiella pneumoniae . Overall concordance with double agar overlay (DAO) was fair (72%). The prototype showed high sensitivity (94.5%) at detecting weak killers and high specificity (87%) at identifying strong killer phages. Most discordances involved DAO weak killers classified as active by the prototype. Most of these discordant phage-bacteria couples produced a spot in the spot test, suggesting the assay may detect but not distinguish killing without replication from killing with replication. The method showed high repeatability and reproducibility. A few aberrant species specificity results highlighted the need for routine controls. Results from prospective urine samples were obtained within an average of 5 h. IMPORTANCE The lack of reproducible user-friendly phage susceptibility testing that can timely inform clinical decisions remains a major barrier to the routine clinical use of phages. We developed a high-throughput, semi-automated prototype that delivers easy-to-interpret phage susceptibility results for four bacterial species within 5 h in a “real-life” clinical flow. However, the correlation between in vitro lytic activity and clinical outcomes still needs to be established to meet regulatory requirements for in vitro diagnostic (IVD) medical devices.

Microbiology Spectrum
Synlab Czech (Czechia) (CZ), Université Libre de Bruxelles (BE), Intel (United States) (US), International Solvay Institutes (BE)
Openalex Percentile: Top 9%
Bacteriophages and microbial interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.