Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies

BACKGROUND: Foreign body ingestion constitutes a common emergency in children. Radiography is essential for confirming presence, type, and location of ingested objects. International guidelines recommend broad anatomical coverage from the neck to the pelvis; however, the impact of radiographic exposure parameters and collimation on radiation dose remains underexplored. OBJECTIVE: To evaluate the effects of different scan protocols on radiation dose in pediatric foreign body ingestion. MATERIALS AND METHODS: Two-hundred-twenty-one radiographs from 183 pediatric patients (median age 2.8 years [interquartile range 1.5-5.5 years]; 112 males, 71 females) performed between September 2019 and April 2025 were retrospectively analyzed. Radiographs were categorized as neck-upper abdomen, extended collimation including pelvis, or abdomen only. Notably, the first two protocols used chest radiograph exposure parameters. Data included patient demographics, foreign body type and location, radiographic protocol, dose-area product, and estimated effective dose. RESULTS: A foreign body was detected in 55.7% of radiographs, most of them in the stomach (59.4%). Coins were most common (31.7%), followed by button batteries (13.8%) and magnets (12.2%). Dose-area products were comparable between standard neck-to-upper-abdomen and extended neck-to-pelvis collimation but were markedly higher for abdomen-only imaging (P<0.001). Effective dose increased with extended collimation (P<0.05) and was highest for abdomen-only radiographs (0.053 mSv [0.034-0.086 mSv], P<0.001). No differences were observed in patient age or repeat imaging rates. CONCLUSION: In suspected pediatric foreign body ingestion, collimation and exposure parameters substantially influence radiation dose. Low-dose chest parameters combined with restrictive collimation minimize radiation exposure, whereas abdominal radiographs carry higher dose, attributable predominantly to the abdominal exposure parameters employed.

Authors

Institutions

Publication Details

Journal
Pediatric Radiology
Published
2026-08-20
DOI
https://doi.org/10.1007/s00247-026-06751-7
Primary Topic
Foreign Body Medical Cases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies

Henner Huflage, Max-Johann Sturm, Anke Dick, Oliver Andrés et al.
Pediatric Radiology
Foreign Body Medical Cases
article

Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies

Henner Huflage, Max-Johann Sturm, Anke Dick, Oliver Andrés, Jan‐Peter Grunz, Clemens Benoit, Thorsten Alexander Bley, Stefan Weick, F Müller-Reichart
article en

Abstract

BACKGROUND: Foreign body ingestion constitutes a common emergency in children. Radiography is essential for confirming presence, type, and location of ingested objects. International guidelines recommend broad anatomical coverage from the neck to the pelvis; however, the impact of radiographic exposure parameters and collimation on radiation dose remains underexplored. OBJECTIVE: To evaluate the effects of different scan protocols on radiation dose in pediatric foreign body ingestion. MATERIALS AND METHODS: Two-hundred-twenty-one radiographs from 183 pediatric patients (median age 2.8 years [interquartile range 1.5-5.5 years]; 112 males, 71 females) performed between September 2019 and April 2025 were retrospectively analyzed. Radiographs were categorized as neck-upper abdomen, extended collimation including pelvis, or abdomen only. Notably, the first two protocols used chest radiograph exposure parameters. Data included patient demographics, foreign body type and location, radiographic protocol, dose-area product, and estimated effective dose. RESULTS: A foreign body was detected in 55.7% of radiographs, most of them in the stomach (59.4%). Coins were most common (31.7%), followed by button batteries (13.8%) and magnets (12.2%). Dose-area products were comparable between standard neck-to-upper-abdomen and extended neck-to-pelvis collimation but were markedly higher for abdomen-only imaging (P<0.001). Effective dose increased with extended collimation (P<0.05) and was highest for abdomen-only radiographs (0.053 mSv [0.034-0.086 mSv], P<0.001). No differences were observed in patient age or repeat imaging rates. CONCLUSION: In suspected pediatric foreign body ingestion, collimation and exposure parameters substantially influence radiation dose. Low-dose chest parameters combined with restrictive collimation minimize radiation exposure, whereas abdominal radiographs carry higher dose, attributable predominantly to the abdominal exposure parameters employed.

Pediatric Radiology
Universitätsklinikum Würzburg (DE)
Good health and well-being
Openalex Percentile: Top 10%
Foreign Body Medical Cases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.