A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning

BACKGROUND: Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planning. Current treatment planning, however, depends on manual forward planning using computationally intensive Monte Carlo (MC) simulations. PURPOSE: We propose an automated patient position optimization framework for BNCT to address these limitations. This method overcomes the computational bottleneck of MC simulations by integrating a rapid deep learning (DL) dose prediction model with a high-fidelity GPU-accelerated MC engine, enabling efficient inverse planning. METHODS: We developed a hybrid coarse-to-fine optimization workflow driven by the Trust Region Bayesian Optimization (TuRBO) algorithm. In the coarse stage, a 3D U-Net architecture rapidly identifies promising patient positions. In the fine stage, the solution is refined within a restricted parameter bound using the GPU-accelerated MC engine. We evaluated the framework on the GLIS-RT open dataset (229 glioblastoma patients, split into train, validation, and test sets at a 70:20:10 ratio). RESULTS: Optimizing the patient position with TuRBO improved target dose and homogeneity over a non-optimized baseline, reaching equivalent plan quality about 5.65× faster than an exhaustive grid search. In the coarse stage, the DL dose predictor ran about 37× faster than the high-fidelity MC. The coarse-to-fine workflow then matched high-fidelity MC plan quality while cutting optimization time by a factor of 2.7, outperforming optimization driven by the DL predictor alone. Two-port plans required no change to the method, where the added geometric freedom raised the mean target dose from 59.96% to 74.91% and lowered the homogeneity index (HI) from 1.226 to 0.647. CONCLUSIONS: We successfully developed a Bayesian optimization (BO) framework for BNCT patient positioning. The proposed coarse-to-fine approach effectively balances computational speed with accuracy, offering a practical way toward automated inverse planning in BNCT.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-08-20
DOI
https://doi.org/10.1002/mp.70642
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning

Jimin Lee, Chang‐min Lee, Hyungjoo Cho, Sung‐Joon Ye et al.
Medical Physics
Boron Compounds in Chemistry
article

A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning

Jimin Lee, Chang‐min Lee, Hyungjoo Cho, Sung‐Joon Ye, Yoonho Na, Kyuri Kim
article en

Abstract

BACKGROUND: Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planning. Current treatment planning, however, depends on manual forward planning using computationally intensive Monte Carlo (MC) simulations. PURPOSE: We propose an automated patient position optimization framework for BNCT to address these limitations. This method overcomes the computational bottleneck of MC simulations by integrating a rapid deep learning (DL) dose prediction model with a high-fidelity GPU-accelerated MC engine, enabling efficient inverse planning. METHODS: We developed a hybrid coarse-to-fine optimization workflow driven by the Trust Region Bayesian Optimization (TuRBO) algorithm. In the coarse stage, a 3D U-Net architecture rapidly identifies promising patient positions. In the fine stage, the solution is refined within a restricted parameter bound using the GPU-accelerated MC engine. We evaluated the framework on the GLIS-RT open dataset (229 glioblastoma patients, split into train, validation, and test sets at a 70:20:10 ratio). RESULTS: Optimizing the patient position with TuRBO improved target dose and homogeneity over a non-optimized baseline, reaching equivalent plan quality about 5.65× faster than an exhaustive grid search. In the coarse stage, the DL dose predictor ran about 37× faster than the high-fidelity MC. The coarse-to-fine workflow then matched high-fidelity MC plan quality while cutting optimization time by a factor of 2.7, outperforming optimization driven by the DL predictor alone. Two-port plans required no change to the method, where the added geometric freedom raised the mean target dose from 59.96% to 74.91% and lowered the homogeneity index (HI) from 1.226 to 0.647. CONCLUSIONS: We successfully developed a Bayesian optimization (BO) framework for BNCT patient positioning. The proposed coarse-to-fine approach effectively balances computational speed with accuracy, offering a practical way toward automated inverse planning in BNCT.

Medical PhysicsVol. 53(9)
Seoul National University (KR), Advanced Institute of Convergence Technology (KR), NCSOFT (South Korea) (KR), Roche (South Korea) (KR), Ulsan National Institute of Science and Technology (KR)
National Research Foundation of Korea, Kementerian Pendidikan
Openalex Percentile: Top 10%
Boron Compounds in Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.