Flow stability and non-monotonic contaminant removal in electronic cleanrooms with pulsating air supply

Pulsed airflow supply is a promising strategy for enhancing cleanroom ventilation by disrupting stagnant zones; yet its dynamic interaction with air change rates (ACH) and human respiration remains complex and under-investigated. This study employed Computational Fluid Dynamics (CFD) coupled with a User-Defined Function (UDF) to model realistic human respiratory effects, comparing pulsed and constant airflow modes across standard cleanroom ACH levels (50, 55 and 60 h −1 ). The numerical model integrated turbulence modelling, Lagrangian particle tracking and transient boundary conditions to capture airflow evolution, particle dispersion and breathing-zone exposure. A quantitative analysis utilizing the Mean Age of Air (MAA), Contaminant Removal Efficiency (E T ) and velocity attenuation coefficient was conducted to evaluate the airflow organization, ventilation effectiveness and contaminant removal performance of each airflow mode. The results showed that pulsed airflow significantly outperformed constant modes, reducing MAA by 42.2% and nearly doubling E T at 60 h −1 . Furthermore, the relationship between ACH and removal effectiveness exhibited non-linear behaviour under dynamic conditions; specifically, performance temporarily degraded at 55 h −1 compared with 50 and 60 h −1 . Consequently, the optimal operational strategy lies in the 55–60 h −1 transition range, balancing momentum-driven scouring with flow stability. These findings provide a robust basis for optimizing cleanroom environments.

Authors

Institutions

Publication Details

Journal
Indoor and Built Environment
Published
2026-08-20
DOI
https://doi.org/10.1177/1420326x261471043
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow stability and non-monotonic contaminant removal in electronic cleanrooms with pulsating air supply

Yueping Fang, Xin Zhang, Fu-Yun Zhao, Shiqing Zhao et al.
Indoor and Built Environment
Infection Control and Ventilation
article

Flow stability and non-monotonic contaminant removal in electronic cleanrooms with pulsating air supply

Yueping Fang, Xin Zhang, Fu-Yun Zhao, Shiqing Zhao, Cheng-Peng Ma
article en

Abstract

Pulsed airflow supply is a promising strategy for enhancing cleanroom ventilation by disrupting stagnant zones; yet its dynamic interaction with air change rates (ACH) and human respiration remains complex and under-investigated. This study employed Computational Fluid Dynamics (CFD) coupled with a User-Defined Function (UDF) to model realistic human respiratory effects, comparing pulsed and constant airflow modes across standard cleanroom ACH levels (50, 55 and 60 h −1 ). The numerical model integrated turbulence modelling, Lagrangian particle tracking and transient boundary conditions to capture airflow evolution, particle dispersion and breathing-zone exposure. A quantitative analysis utilizing the Mean Age of Air (MAA), Contaminant Removal Efficiency (E T ) and velocity attenuation coefficient was conducted to evaluate the airflow organization, ventilation effectiveness and contaminant removal performance of each airflow mode. The results showed that pulsed airflow significantly outperformed constant modes, reducing MAA by 42.2% and nearly doubling E T at 60 h −1 . Furthermore, the relationship between ACH and removal effectiveness exhibited non-linear behaviour under dynamic conditions; specifically, performance temporarily degraded at 55 h −1 compared with 50 and 60 h −1 . Consequently, the optimal operational strategy lies in the 55–60 h −1 transition range, balancing momentum-driven scouring with flow stability. These findings provide a robust basis for optimizing cleanroom environments.

Indoor and Built Environment
Wuhan University (CN), Hunan University of Technology (CN), Coventry University (GB)
National Key Research and Development Program of China
Industry, innovation and infrastructure
Openalex Percentile: Top 11%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flow stability and non-monotonic contaminant removal in electronic cleanrooms with pulsating air supply — Yueping Fang, Xin Zhang, et al. · Indoor and Built Environment (2026) | TGRS Research Map | TGRS