Corrosion Behavior of N80 Steel Under Coalbed Methane Conditions

The corrosion behavior of N80 steel in a simulated coalbed–methane environment was investigated in a high-temperature, high-pressure autoclave. Uniform corrosion and maximum pit depth were quantified by weight-loss measurements and ultra-depth-of-field three-dimensional microscopy, respectively, while SEM, EDS, and XRD were used to characterize the morphology, elemental composition, and crystalline phases of the surface corrosion products. A one-factor-at-a-time design was applied at a constant total pressure of 10 MPa to evaluate the effects of nominal CO2 partial pressure (0.10–1.00 MPa), nominal O2 partial pressure (0–0.40 MPa), Cl− concentration (3–187 g/L), and temperature (40–75 °C). Increasing the nominal CO2 partial pressure raised the uniform corrosion rate from 0.712 to 0.930 mm/a but reduced the maximum pitting corrosion rate from 1.691 to 0.280 mm/a, while FeCO3-containing surface coverage increased. Increasing the nominal O2 partial pressure intensified both corrosion modes; at 0.40 MPa, the uniform and maximum pitting corrosion rates reached 1.446 and 2.202 mm/a, respectively, and the corrosion-product layer exhibited extensive cracking and spallation. Increasing the Cl− concentration reduced the uniform corrosion rate from 1.078 to 0.839 mm/a but increased the maximum pitting corrosion rate from 0.474 to 1.807 mm/a, indicating a shift in the principal damage risk from average metal loss to localized penetration. The uniform corrosion rate reached a maximum of 1.516 mm/a at 60 °C, whereas the maximum pitting corrosion rate increased continuously to 2.202 mm/a at 75 °C. XRD identified Fe, FeCO3, Fe2O3, Fe3O4, and FeOOH. The persistent Fe substrate reflections, interpreted together with the SEM observations, revealed spatially heterogeneous corrosion-product coverage. These results show that the protective contribution of FeCO3-containing products depends on their surface coverage and visible integrity rather than on phase presence alone. The findings support stringent oxygen-ingress control, targeted pitting protection in high-salinity environments, and enhanced corrosion surveillance of intermediate- and high-temperature well sections.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2026-08-20
DOI
https://doi.org/10.3390/coatings16080993
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Behavior of N80 Steel Under Coalbed Methane Conditions

Xiaofei Cao, Manxiang Li, J. Liu, Shijun Chen et al.
Coatings
Corrosion Behavior and Inhibition
article

Corrosion Behavior of N80 Steel Under Coalbed Methane Conditions

Xiaofei Cao, Manxiang Li, J. Liu, Shijun Chen, Chaoming Wang, Juantao Zhang, Ning Liu, Baojun Zheng
article en

Abstract

The corrosion behavior of N80 steel in a simulated coalbed–methane environment was investigated in a high-temperature, high-pressure autoclave. Uniform corrosion and maximum pit depth were quantified by weight-loss measurements and ultra-depth-of-field three-dimensional microscopy, respectively, while SEM, EDS, and XRD were used to characterize the morphology, elemental composition, and crystalline phases of the surface corrosion products. A one-factor-at-a-time design was applied at a constant total pressure of 10 MPa to evaluate the effects of nominal CO2 partial pressure (0.10–1.00 MPa), nominal O2 partial pressure (0–0.40 MPa), Cl− concentration (3–187 g/L), and temperature (40–75 °C). Increasing the nominal CO2 partial pressure raised the uniform corrosion rate from 0.712 to 0.930 mm/a but reduced the maximum pitting corrosion rate from 1.691 to 0.280 mm/a, while FeCO3-containing surface coverage increased. Increasing the nominal O2 partial pressure intensified both corrosion modes; at 0.40 MPa, the uniform and maximum pitting corrosion rates reached 1.446 and 2.202 mm/a, respectively, and the corrosion-product layer exhibited extensive cracking and spallation. Increasing the Cl− concentration reduced the uniform corrosion rate from 1.078 to 0.839 mm/a but increased the maximum pitting corrosion rate from 0.474 to 1.807 mm/a, indicating a shift in the principal damage risk from average metal loss to localized penetration. The uniform corrosion rate reached a maximum of 1.516 mm/a at 60 °C, whereas the maximum pitting corrosion rate increased continuously to 2.202 mm/a at 75 °C. XRD identified Fe, FeCO3, Fe2O3, Fe3O4, and FeOOH. The persistent Fe substrate reflections, interpreted together with the SEM observations, revealed spatially heterogeneous corrosion-product coverage. These results show that the protective contribution of FeCO3-containing products depends on their surface coverage and visible integrity rather than on phase presence alone. The findings support stringent oxygen-ingress control, targeted pitting protection in high-salinity environments, and enhanced corrosion surveillance of intermediate- and high-temperature well sections.

CoatingsVol. 16(8)
Xi'an Shiyou University (CN), State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation (CN), University of Petroleum (ID), Oil and Gas Center (CN), China National Petroleum Corporation (China) (CN)
Openalex Percentile: Top 22%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.