Optimization of an Evacuated Tube Assisted Ground Source Heat Pump System With Slinky‐Coil Ground Heat Exchanger Using Taguchi Method

ABSTRACT The study proposes a methodology to optimize an evacuated‐tube collector (ETC) coupled solar‐assisted ground source heat pump (SAGSHP) system integrated with a horizontal slinky‐coil ground heat exchanger (GHE) to exploit shallow geothermal energy in North East India. The system is optimized for both heating and cooling, using Taguchi L 27 array and utility‐based multi‐objective framework, applying local heating/cooling degree‐day weighting to select one parameter set that minimizes collector area and GHE length while improving collector efficiency and system COP. The model couples ETC/GHE internal convection and geothermal physics, accounting for adjacent slinky loop thermal interaction and depth‐dependent ground‐temperature profile. Parameters such as ETC absorptivity, ETC/GHE pipe diameters, GHE flow rate, parameters influencing GHE geometry and depth were systematically varied and assessed by signal‐to‐noise ratios and ANOVA. Taguchi optimum parameter levels indicate ETC area of 1.76 m 2 at 55.4% efficiency, GHE lengths of 56.4 m (heating), 91.6 m (cooling), COPs of 4.17 (heating) and 3.46 (cooling). ANOVA shows absorptivity drives ETC metrics: 48% (area) and 56% (efficiency). GHE mass‐flow governs subsurface design and performance: 36% (heating length), 50% (cooling length), 26% (heating COP), 49% (cooling COP), while GHE geometry contributes 7%–25% and depth 13%. Utility reflects the site's subtropical climate, selecting cooling‐aligned settings, giving 1.76 m 2 ETC area at 55.4% efficiency, GHE lengths 89.7 m (heating) and 91.6 m (cooling), COPs 3.99 (heating) and 3.46 (cooling) for energy efficiency.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2026-08-20
DOI
https://doi.org/10.1002/htj.70349
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of an Evacuated Tube Assisted Ground Source Heat Pump System With Slinky‐Coil Ground Heat Exchanger Using Taguchi Method

Rahul Tarodiya, Vikas Verma, Avishek RaiBaruah
Heat Transfer
Geothermal Energy Systems and Applications
article

Optimization of an Evacuated Tube Assisted Ground Source Heat Pump System With Slinky‐Coil Ground Heat Exchanger Using Taguchi Method

Rahul Tarodiya, Vikas Verma, Avishek RaiBaruah
article en

Abstract

ABSTRACT The study proposes a methodology to optimize an evacuated‐tube collector (ETC) coupled solar‐assisted ground source heat pump (SAGSHP) system integrated with a horizontal slinky‐coil ground heat exchanger (GHE) to exploit shallow geothermal energy in North East India. The system is optimized for both heating and cooling, using Taguchi L 27 array and utility‐based multi‐objective framework, applying local heating/cooling degree‐day weighting to select one parameter set that minimizes collector area and GHE length while improving collector efficiency and system COP. The model couples ETC/GHE internal convection and geothermal physics, accounting for adjacent slinky loop thermal interaction and depth‐dependent ground‐temperature profile. Parameters such as ETC absorptivity, ETC/GHE pipe diameters, GHE flow rate, parameters influencing GHE geometry and depth were systematically varied and assessed by signal‐to‐noise ratios and ANOVA. Taguchi optimum parameter levels indicate ETC area of 1.76 m 2 at 55.4% efficiency, GHE lengths of 56.4 m (heating), 91.6 m (cooling), COPs of 4.17 (heating) and 3.46 (cooling). ANOVA shows absorptivity drives ETC metrics: 48% (area) and 56% (efficiency). GHE mass‐flow governs subsurface design and performance: 36% (heating length), 50% (cooling length), 26% (heating COP), 49% (cooling COP), while GHE geometry contributes 7%–25% and depth 13%. Utility reflects the site's subtropical climate, selecting cooling‐aligned settings, giving 1.76 m 2 ETC area at 55.4% efficiency, GHE lengths 89.7 m (heating) and 91.6 m (cooling), COPs 3.99 (heating) and 3.46 (cooling) for energy efficiency.

Heat Transfer
Tezpur University (IN), Visvesvaraya National Institute of Technology (IN)
U.S. Department of Energy, Tezpur University
Affordable and clean energy
Openalex Percentile: Top 27%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.