The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast‐Enhanced MRI in Patients Treated for Severe Aortic Stenosis

PURPOSE: To investigate the impact of intra/extracellular water exchange (WX) on quantitative dynamic contrast-enhanced (DCE) MRI in patients with severe aortic stenosis (AS). The aims were to compare low-dose (WX insensitive) and high-dose (WX sensitive) DCE-MRI measurements, and to compare data acquired before and after aortic valve replacement (AVR) to test whether DCE-MRI was able to detect changes in myocardial extracellular volume fraction (ECV). METHODS: Twenty-five patients with severe AS were studied at 3 T before and 6 months after AVR. DCE-MRI was performed at rest twice using a low contrast agent dose (0.05 mmol/kg gadobutrol) followed by a high-dose (0.1 mmol/kg gadobutrol). Estimates of myocardial blood flow (MBF) and ECV were obtained using models which assume instantaneous WX (fast exchange [FX]) and which incorporate WX (a two-site exchange [2SX] model). ECV estimates were also made using T1 maps acquired before and after contrast administration, both assuming FX and incorporating WX. RESULTS: FX model estimates of MBF and ECV obtained before AVR decreased from low- to high-dose contrast consistent with the effect of limited WX. This decrease was partially corrected using a 2SX model. However, 2SX model fits were preferred over FX fits in only 2 of 24 high-dose data sets (F-test). ECV estimates made using DCE-MRI increased after AVR consistent with changes seen using T1 maps, but the ECV estimates were lower. CONCLUSION: Estimates of MBF using DCE-MRI showed negligible sensitivity to WX. DCE-MRI-based ECV estimates changed post-AVR but were systematically lower than those made using T1 maps.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-08-20
DOI
https://doi.org/10.1002/mrm.70571
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast‐Enhanced MRI in Patients Treated for Severe Aortic Stenosis

Noor Sharrack, John Biglands, David L. Buckley, Alex Makins et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast‐Enhanced MRI in Patients Treated for Severe Aortic Stenosis

Noor Sharrack, John Biglands, David L. Buckley, Alex Makins, Sven Plein, Peter Kellman
article en

Abstract

PURPOSE: To investigate the impact of intra/extracellular water exchange (WX) on quantitative dynamic contrast-enhanced (DCE) MRI in patients with severe aortic stenosis (AS). The aims were to compare low-dose (WX insensitive) and high-dose (WX sensitive) DCE-MRI measurements, and to compare data acquired before and after aortic valve replacement (AVR) to test whether DCE-MRI was able to detect changes in myocardial extracellular volume fraction (ECV). METHODS: Twenty-five patients with severe AS were studied at 3 T before and 6 months after AVR. DCE-MRI was performed at rest twice using a low contrast agent dose (0.05 mmol/kg gadobutrol) followed by a high-dose (0.1 mmol/kg gadobutrol). Estimates of myocardial blood flow (MBF) and ECV were obtained using models which assume instantaneous WX (fast exchange [FX]) and which incorporate WX (a two-site exchange [2SX] model). ECV estimates were also made using T1 maps acquired before and after contrast administration, both assuming FX and incorporating WX. RESULTS: FX model estimates of MBF and ECV obtained before AVR decreased from low- to high-dose contrast consistent with the effect of limited WX. This decrease was partially corrected using a 2SX model. However, 2SX model fits were preferred over FX fits in only 2 of 24 high-dose data sets (F-test). ECV estimates made using DCE-MRI increased after AVR consistent with changes seen using T1 maps, but the ECV estimates were lower. CONCLUSION: Estimates of MBF using DCE-MRI showed negligible sensitivity to WX. DCE-MRI-based ECV estimates changed post-AVR but were systematically lower than those made using T1 maps.

Magnetic Resonance in Medicine
National Institutes of Health (US), University of Leeds (GB), Leeds Teaching Hospitals NHS Trust (GB), National Heart, Lung, and Blood Institute (US)
British Heart Foundation
Clean water and sanitation
Openalex Percentile: Top 10%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.